9900-1BC Batch Controller Manual
Start Batch
Press Up or Down arrows to select the desired batch number.
Press ENTER to start selected batch. Selected batch alternately displays on the bottom line of the display.
(Confirmation screen or password screen are user-selectable in INPUT menu.)
Available batches determined by the number of stored batches whose size is not zero.
Resume/Cancel Batch
Displays when a batch is stopped without completing. Press the ► key to select
either RESUME or CANCEL and then press ENTER to either resume the batch or cancel it. A confirmation
or password screen for resuming a batch is user selectable. This screen will not display if the batch
reaches completion.
Override Batch
In Simple mode the user can temporarily change the size of the batch. The batch returns
to the programmed value at the end of the current batch run.
In Advanced mode the Override can be set to permanently change the size of the batch value.
A batch is overridden by pressing the ► to edit the batch size.
Manual Batch
is used for “topping off” a batch, after the batch has completed. The Batch Controller will
open the valve as long as the user simultaneously holds down the ▼ and ► keys.
Source Volume
shows the calculated remaining source volume. Displays if SOURCE VOLUME is ON.
Reset source volume with ► key.
Note:
If PWD REQUIRED is set to YES, you may be prompted to enter your password. PWD REQUIRED
setting can be changed in the OPTIONS menu.
Reset Volume?
Confirmation screen for resetting SOURCE VOLUME. Press ▲ or ▼ to select YES and
press ENTER to reset source volume.
Resettable Totalizer
displays the resettable totalizer. Press ► to reset the totalizer.
Note:
If PWD
REQUIRED is set to YES, you may be prompted to enter your password. PWD REQUIRED setting can be
changed in the OPTIONS menu.
Reset Total?
Confirmation screen for clearing the resettable Totalizer. Press ▲ or ▼ to select YES and
press ENTER.
Permanent Totalizer
displays the Permanent Totalizer value (note the "P" indicating Permanent).
Pressing ► displays units of measure.
Overrun
displays the amount of overrun volume detected after the 9900-1BC deactivates the batch relay,
triggering valve closure. Overrun resets each time a new batch starts.
Batch Count
shows the number of batches which have run to at least 90% of completion. Press ► to
reset Batch Count.
Note:
If PWD REQUIRED is set to YES, you may be prompted to enter your password. PWD REQUIRED
setting can be changed in the OPTIONS menu.
Reset Count?
Confirmation screen for clearing the Batch Count. Press ▲ or ▼ to select YES and
press ENTER.
Customizable Label
is the View name assigned to the 9900.
Default is BATCH for 9900-1BC.
VIEW Mode Menu - Batch Stopped