Operating Manual MSA 330 /MSA 340
2 Fusion process
7
2.2
Switching On
Before connecting the machine to the power source, the
operator
must
read
the
chapter
8
‘Technical
characteristics‘!
Check the voltage!
The generator has to be started before connecting the
electro-fusion unit and must supply a constant output
voltage! Any sudden changes could compromise the correct
welding result and/or damage the control unit.
MSA 340
S/N: S160B5911011
SW vers. :
1.02
Next revision: 05/11
Connect the machine to the power mains or generator, already started,
and switch on the machine. The display shows the machine information
(machine type, serial number, software version and date of the next
revision).
2.3
Enter work site details
2.3.1
Operator Identity
At the beginning the user can add some work site information, like the
welder identity and the job number for the next set of welding.
The OPERATOR IDENTITY functionality must be enabled in the
configuration menu (see ‘Configuration’ chapter).
OPERATOR IDENTITY
--------------
Esc OK
In the OPERATOR IDENTITY page, the user can insert the operator code
by reading the barcode printed out in the welder pass, or by inserting
the name manually.
In the latter case, by pushing the buttons (
) and (
) the user may
select the desired characters; while pushing the buttons (
) and (
) he
may move the cursor. To confirm, and go to the next page, push
START/OK ( I ).
Attention
Caution