1 2 3 4 5 6 7 8 9 10 11 12 13 14
SS CNT GND PLS
OUTPUT
ANL2
R+ R-
SERIAL
Tx GND Rx
A in
A+ A-
BLK RED SHLD
SENSOR
Red (2)
Shld (3)
+GF+ SIGNET
Indicator or
Controller
OR
TTL
Compatible
Device
Input
Gnd
Gnd 5 to 30 VDC
Power Supply
+
External counter
or accumulator
IN
Gnd
600
Ω
@ >1.5 W
To reduce the possibility of
noise interference, separate
output lines from AC power
lines.
Figure 5
Sensor pulse output (PLS)/
counter output (CNT)
wiring
7
2.4 Standard Output Connections
Standard Outputs
An open collector counter pulse output (CNT) and
a sensor pulse output (PLS) are included with your
unit.
The counter pulse output (synchronous w/totalizer)
emits an open collector 150 ms pulse with a
maximum
current sinking capacity of 50 mA @
30 VDC, and is ideal for driving an external
counter or accumulator.
An external DC power
supply and current limiting resistor are required
for operation.
The sensor pulse output (PLS) emits a standard TTL
frequency output in phase with the sensor input
and can be used to drive +GF+ SIGNET
instruments (GF+ SIGNET 5090 and
5091) and other TTL compatible devices.