26
Planungsunterlage TSA160 Datei 84338PuTSA160_GB_200999_.p65
Cable plan
single-leaf door
In addition:
Wiring diagram 70423/9-9750
Cable plan single-leaf
TSA 160
230V 50Hz
Main
switch
Emergeny
cut-off
switch
Key-
operated
switch
inside
Contactor
inside
Programme
switch
Movement
detector
inside
(see sketch
A)
Cable outlet
for door drive
Door drive
TSA 160
Movement
detector outside
(see sketch A)
Contactor
outside
Key-
operated
switch
outside
Sensor strips
and / or
and / or
Power supply line
230V/50Hz
Fuse 16 A
Connected load 200 W
8-pole door
transition cable
incl.connecting box
(provided by GEZE)
Door opener
Lock switch contact
Sketch A
For the installation and operation of the entire system the
guidelines (ZH1/494) for power-operated windows, doors
and gates (issued by the Association for Accident
Prevention and Industrial Medicine, 53757 Sankt Augustin)
have to be observed. In addition to this the mounting and
operating instructions as well as all other documents
refering to this product have to be observed.
Allow cable to protrude at least 1 m out of the wall
Note:
Any warranty and service agreements will
be rejected if GEZE products are combined
with third-party products.
Cross-sections of cable
1
= NYM-J 3x1,5 mm²
2
= J-Y(ST)Y 2x4x0,6 mm
3
= J-Y(ST)Y 2x2x0,6 mm
4
=
Cable conduit with
Ø16 mm
Positioning of the movement
detectors