RS5
RS5
Ceiling mounted
alarm
Cable plan
single-leaf smoke and fire-proof door, incl. central smoke control unit
Cable plan single-leaf
TSA 160 F incl. RSZ 6
230 V 50 Hz
Breaker
contact
“close door”
Allow cable to protrude at least 1 m out of the wall
IMPORTANT:
The breaker contact must be installed in close
proximity to the door and must not be concealed by
the open door
Note:
Any warranty and service agreements will
be rejected if GEZE products are combined
with third-party products.
Cross-sections of cable
1
= NYM-J 3x1,5 mm²
2
= J-Y(ST)Y 2x4x0,6 mm
3
= J-Y(ST)Y 2x2x0,6 mm
4
= Cable conduit with Ø16 mm
5
= J-Y(ST)Y 2x0,6 mm
Main
switch
Emergeny
cut-off
switch
Power supply line
230V/50Hz
Connected load 200 W
Key-
operated
switch
inside
Contactor
inside
Programme
switch
Movement
detector
inside
(see sketch
A)
Cable outlet for
door drive
(acc. to
sketch A)
Door drive
TSA 160F
Movement
detector outside
(see sketch A)
Contactor
outside
Key-
operated
switch
outside
Sensor strips
and / or
and / or
8-pole door
transition cable
incl.connecting box
(provided by GEZE)
Door opener
Lock switch contact
In addition:
Wiring diagram 70423/9-9750
Sketch A
For the installation and operation of the entire system the guidelines
(ZH1/494) for power-operated windows, doors and gates (issued by
the Association for Accident Prevention and Industrial Medicine,
53757 Sankt Augustin) have to be observed. In addition to this the
mounting and operating instructions as well as all other documents
refering to this product have to be observed.
Positioning of the movement
detectors
Fuse 16 A
RSZ 6