10
Planungsunterlage TSA160 Datei 84338PuTSA160_GB_200999_.p65
TSA 160 WC-compartments for the handicapped
Functional description
After the pad switch had been operated, the toilet door opens and closes automatically upon lapse
of a presettable hold-open time.
By operating the changeover switch inside the toilet cabin, the user activates the illuminated sign
“OCCUPIED“ outside the compartment as well as the control lamp at the changeover switch.
Simultaneously the interior and exterior pad switch is switched off. Thus the door can neither be
opened by a third person nor by the user himself by accident.
The live door opener prevents that the doors can be opened manually.
To leave the lavatory, the user again operates the changeover switch; the sign “ OCCUPIED“ out-
side the compartment as well as the
control lamp go out.
By operating the interior pad switch
“DOOR OPEN“, the door will immediately
open.
In the case of power failure the user has
the possibility to open the door manually
by pushing or pulling it open, the closed-
circuit opener is unlocked.
The door can also be opened from inside
by operating the door handle even if the
system is live. In an emergency the door
can also be manually opened from out-
side using a key or by operating the
emergency cutout.
TSA160
Illuminated sign
“OCCUPIED“
Pad switch “DOOR
OPEN“ (inside and
outside)
Emergency
cutout
Door
opener
Changeover
switch
locked/unlocked
Illuminated sign
“OCCUPIED“