TS 5000 R-ISM BG
Mounting and securing
GB 9
Stop rod may not pass under driver.
X
Pull out stop rod (
3.
).
Distance between edge block and stop is approx. 30 mm
X
Close moving leaf (
4.
).
Stop rod for function safeguard of the integrated closing sequence control is in position.
X
Open moving leaf (
5.
).
X
Tighten screws of stop rod (
6.
)
6.12 Mounting cover panels
CAUTION!
X
Do not pinch cable.
B
D
C
(5)
(5)
35
35
GF
SF
A
C
C
= B - 1189 mm
= D - 10 mm
2.
2.
3.
4.
5.
5.
1.
Fig. 6.12.1
Important: The smoke detector opening from the middle cover panel must be positioned over the smoke detector.
If necessary, dimension „D“ can be measured between the leaf cover panels.
X
Remove break-off section on fixed leaf for trigger lever (
1.
).
X
Clip on moving-leaf cover panel and fixed-leaf cover panel (
2
.).
X
Shorten adjustable-size middle cover panel „A“ to size „C“ (
Fig. 6.12.1
).
X
Clip on middle cover panel (
3.
).
X
Clip on protective cap (
4.
).
X
Insert inspection caps between cover panels (
5.
).
CAUTION!
X
Attach protective cap in such a way that the smoke switch opening is concealed in the cover to protect
the interior of the system from contamination.
Protective cap must be removed during commissioning of the hold-open device.