TS 5000 E-ISM BG
GB 6
Mounting and securing
1.
5.
7.
4.
8.
2.
3.
6.
6.
4.
30-50
M3x10
M3x10
M6x14
SW5
Fig.: 6.5.2
6.6 Mount sliding lever to moving leaf and connect with sliding block
In the delivery condition, the door edge hinders the correct fitting of the sliding lever on the door closer.
The notch must be placed in the hexagonal bolt of the door closer in alignment with the sliding lever.
Fig.: 6.6.1
X
Close closing-time valve (
1.
).
X
Set sliding lever in place (
2.
).
X
Turn sliding lever about 45° to position the notch (
3.
).
X
Remove sliding lever (
4.
).
Now the sliding lever can be appropriately attached to the notch.
X
Align and fit sliding lever with notch (
5.
).
X
Fix sliding lever (tightening torque 14 Nm) (
6.
).
X
Connect sliding lever to sliding block (tightening torque: 5 Nm) (
7.
).
X
Open closing-time valve again (
8.
).