background image

SPEEDCUT

50

1 Phase 240V +/- 15%

MIN GENERATOR 

(8.5kVA at 0.8 PF) 

MIN 100 L/m - 75 psi

ERROR

FOR CONSUMABLES & SUPPORT GO TO WWW.SWSWELDING.COM.AU

DISPLAY CODES

ERROR! Under Pressure

ERROR! Missing Shield Cup

ERROR! Missing Electrode or Nozzle

ERROR! Over Temperature

QUICK REFERENCE GUIDE 

CONTROL DIAL FUNCTIONS

NEGATIVE CENTRAL TORCH LEAD PORT

AIR INLET FITTING (ON BACK OF MACHINE)

ON/OFF SWITCH (ON BACK OF MACHINE)

POSITIVE GROUND CLAMP CABLE PORT

OPERATORS MANUAL 

When illuminated refer to error code on display and resolve.

Amperage control/Press for 2 seconds for air test press to stop. 

Read operators manual before use - download from 

swswelding.com.au

Air pressure is below 60 PSI.

Shield cup is damaged or missing; torch lead is not connected 

securely (Inspect & replace or install).

Electrode or nozzle is excessively worn or missing (Inspect & replace or install). 

Machine has reached duty cycle limit allow to cool. 

CAUTION! Only use clean, dry air for optimum 

cutting performance and to prevent premature 

servicing of internal regulator filter.

CAUTION! Ensure compressor/gas regulator 

pressure is set between 75 - 100 PSI. 

Exceeding 100 PSI can damage the internal 

regulator. 

Move to different mains power outlet, eliminate 

or reduce extension lead, use higher output 

generator, reduce cutting amperage.

i

i

POWER

When illuminated the power source is on.

i

O.T

When illuminated machine is over temperature, do not turn 

off and allow to perform cooling cycle.  

i

i

DIGITAL DISPLAY

Amperage setting , real time amperage display, error codes.

i

i

i

i

i

i

ERROR! Over Voltage

Incorrect input voltage supplied damage may have been caused. 

Contact support if persists.  

50

CAUTION! If the mains power supply/generator 

is not sufficient, the machine will not maintain 

a cutting arc, and it may damage the 

power source.  