Slimdrive SL NT product family
16
Device safety test and production test
5.12 Connecting rechargeable battery and control unit
1
CAUTION!
Danger of injury due to impact and crushing!
When the rechargeable battery cable (1) is plugged in, the pulley on the motor gear unit can move unexpectedly.
X
Do not reach into the area with moving parts.
X
Check whether the rechargeable battery cable (1) is long enough.
X
If necessary, plug the rechargeable battery extension cable to the rechargeable battery cable.
X
Lay rechargeable battery cable (1) to the control unit.
X
Insert the connector into the control unit.
6
Device safety test and production test
WARNING!
Risk of fatal injury due to electric shock!
X
The electrical system (230 V/115 V) may only be connected and disconnected by a qualified electrician
or a qualified electrician for specified tasks.
X
Carry out device safety test in accordance with EN 60335-1 Appendix A.
The device safety test is made up of the following parts:
à
Protective earth test with 10 A test current
à
Dielectric strength test (high-voltage test) with 1000 VAC
The use of a test device suitable for this standard is necessary for this.
Test procedure
X
Connect mains cable with mains plug to the transformer.
X
Insert mains plug into test device.
X
Start test on test device.
X
Test all the metal parts connected to protective earth one after the other using the probe.
The low-impedance connection between the PE conductor of the mains cable and the metal part contacted
with the probe is checked during this process.
Contact at least the following test points with the probe:
à
Metal bracket transformer
à
PE connection on the secondary side of the transformer (lustre terminal)
à
Track (bright, not anodised spot)
à
Device flat plug for earth connection transformer
à
Optional 2
nd
device flat plug for earth connection hood
All protective earth connections must have a resistance smaller than 0.1 Ω.