Cleaning and maintenance
6
Cleaning and maintenance
6.1 Cleaning
CAUTION!
Danger of injury due to impact and crushing!
X
Set the mode of operation to OFF.
X
Secure door leaves against accidental movement before carrying out cleaning work.
What is to be cleaned?
How is it to be cleaned?
Closing safety sensor (SIS) (e.g. light switch)
X
Wipe with damp cloth
Glass surfaces
X
Wipe with a cold vinegar/water mixture; then dry.
Stainless surfaces
X
Wipe with soft cloth
Painted surfaces
X
Wipe with water and soap
Anodised surfaces
X
Wipe with non-alkaline potassium soap (pH value 5.5…7)
Display programme switch
X
Wipe with soft cloth. Do not use a cleaning agent
6.2 Maintenance
The owner must ensure that the system is working perfectly. To guarantee perfect operation, the door system
must be serviced regularly by a service technician.
Maintenance must be carried out at least once a year or according to the maintenance display on the display
programme switch.
Installation, maintenance and repair work must be performed by properly trained personnel authorised by GEZE.
If a dot appears in the bottom right-hand part of the display, maintenance is due.
X
Notify a service technician.
The maintenance display lights up after the specified calendar period or number of opening cycles, depending
on what occurs first:
Powerturn (F) 1 year or 500,000 cycles
GEZE offers maintenance contracts with the following services:
à
Inspection of fixing elements for firm fit
à
Performance of miscellaneous adjustment work
à
Performance of operational checks
à
Checking all the safety and control equipment of the door system
à
Lubrication of all the moveable parts
6.3 Inspection by an expert
In compliance with the “Guidelines for windows, doors and gates” (ASR A1.7 and GUV 16.10) Section 6, power-operat-
ed doors must be inspected for safety by a trained professional before initial commissioning and at least once a year.
GEZE offers the following services:
Inspection and operational checks of all safety and control equipment in compliance with the requirements in the
test log for power-operated windows, doors and gates; Sliding doors and sliding gates ZH 1/580.2 edition.