![GEZE IQ lock AUT Commissioning And Connection Instructions Download Page 4](http://html.mh-extra.com/html/geze/iq-lock-aut/iq-lock-aut_commissioning-and-connection-instructions_2219187004.webp)
IQ lock AUT, EL / EL DL, EM / EM DL, C / C DL, M / M DL
4
Safety notices
1
Safety notices
1.1 Intended use
Self-locking panic locks are components used to lock emergency exit doors/panic exit doors on rescue routes.
When self-locking anti-panic locks are used, the technical data and environment conditions of these installation
and operating instructions must be taken into account.
The safety features of these products are important for correlation with EN 179 and EN 1125. No modifications of
any kind are permitted other than those described in these instructions.
X
Operate the locks only in installation positions typical for locks i.e. vertical with horizontally locking crossbar.
X
Always operate the locks in such a way that the panic function works in the direction of emergency exit.
X
Use these locks on emergency exit doors in accordance with EN 179 and panic exit doors in accordance with
EN 1125 only in connection with the officially approved sliding fitting systems (see certificates for consistency
of performance, chapter 7).
The self-locking panic locks are suitable for use on single- and double-leaf panic doors.
à
They are not designated for use on double-action doors.
à
Use in transport technology (pedestrian traffic and transport of goods by road, rail, air and water) must be
agreed with the manufacturer.
The product should be installed or incorporated in such a way that effortless access to the product is guaranteed
during any repairs and/or maintenance, and that any removal costs do not stand out of proportion to the value of
the product.
Trouble-free functioning of the locks is only ensured if a carry bar and a door closer system in accordance with EN
1158 with closing sequence control are mounted.
Before mounting the emergency exit locks ensure that the door is fitted properly and not distorted in any way.
X
Install the emergency exit locks only in hollow doors that are designed for this purpose by the manufacturer.
The horizontal bar must be mounted in such a way that the greatest possible effective bar length is achieved.
X
Avoid safety risks during the installation of emergency exit devices with handle operation (in particular in case
of doors with graded surfaces: jamming of fingers or clothes).
X
If necessary, adapt installation to the majority of the users:
à
Installation height for children smaller than 900–1000 mm
à
Door closer installation in such a way that children, elderly or impaired persons are not impeded
Only devices conforming to standard may be used for keeping emergency exit and panic exit doors closed.
In correlation with the specifications of German building regulation laws, a lock of the VS-type A in accordance
with DIN EN 179 or DIN 1125 (lock only for 1-leaf doors) can also be used in the active leaf of a 2-leaf door if:
a) the passive leaf lock is secured against maloperation and
b) the passage clearance of the active leaf is sufficient for an escape route.
1.2 Technical safety
à
Improper installation and maintenance work or repairs can lead to significant hazards for the user. Installation
and maintenance work or repairs may only be carried out by GEZE and their authorised specialists.
à
Damage to GEZE IQ locks can endanger your safety. Check them for visible signs of damage. Never put a
damaged lock into operation.
Summary of Contents for IQ lock AUT
Page 56: ...IQ lock AUT EL EL DL EM EM DL C C DL M M DL 56 Wiring diagrams ...
Page 66: ...IQ lock AUT EL EL DL EM EM DL C C DL M M DL 66 Annex ...
Page 68: ...IQ lock AUT EL EL DL EM EM DL C C DL M M DL 68 Annex ...
Page 70: ...IQ lock AUT EL EL DL EM EM DL C C DL M M DL 70 Annex ...
Page 71: ...IQ lock AUT EL EL DL EM EM DL C C DL M M DL 71 Annex ...