Electrical connection
DIP switch (back of PCB)
à
The DIP switch (1) can be used to switch the terminating resistor for RS485 on and off.
à
If there are more than two bus participants, the resistance must be switched on in the first and last device.
43
ON
OFF
22 x1
21
20
52
31
41
42
2
1
X4
1
5.2.2 Service menu
Level 0
Level 1
Level 2
Value range
Factory setting
Note
Configuration
speed
45% to 85%
60%
Hold-open time
2 to 60 sec
10 sec
Language
à
English
à
French
à
English
English
Output 1
à
Locked
à
SW + 6 sec
à
Alarm
Locked
See below
Fire protection
Yes/no
no
See below
System information Maintenance
Yes/no
Yes: When maintenance
is due
System init.
Yes/no
Yes: When system is
initialised
Motor replaced
Yes/no
Yes: When the motor was
replaced
Cycle
[Number of
cycles]
The current number of
cycles
Product
information
HW ver.
Vx.x
SW ver.
Vx.x
Ser. no.
xxxxxx
Diagnosis
Motor state
Current (A)
The value is updated as
long as the enter key on
ST220 is kept pressed.
Temperature
Duration (sec)
Current state
Sensor state
[see below]
Alarm memory
[Cycle]
[Alarm description]
See fault description
Command
Start motor
Acknowledge
alarm
Factory setting
Summary of Contents for IQ lock AUT
Page 56: ...IQ lock AUT EL EL DL EM EM DL C C DL M M DL 56 Wiring diagrams ...
Page 66: ...IQ lock AUT EL EL DL EM EM DL C C DL M M DL 66 Annex ...
Page 68: ...IQ lock AUT EL EL DL EM EM DL C C DL M M DL 68 Annex ...
Page 70: ...IQ lock AUT EL EL DL EM EM DL C C DL M M DL 70 Annex ...
Page 71: ...IQ lock AUT EL EL DL EM EM DL C C DL M M DL 71 Annex ...