Parameter setting
10 Parameter setting
The following is possible with the parameter setting unit ST 220:
à
Configuration of drive activation
à
Blocking the “turn position” control key. This prevents the drive system moving to this position.
à
Changing parameter values
à
Reading out diagnosis values
à
Reading out faults, errors, warnings and displaying information
The options for adjusting and setting parameters for the F 1200+ drive system are described in the user manual
IQ windowdrives (ID 153523) of the ST 220.
10.1 Parameter setting with service case
Parameters can be set for the drive system using the GEZE service case (ID 142586) and the parameter setting
unit ST 220 (ID 087261).
More information can be found in the instructions for the GEZE service case (ID 144097).
For the drive F 1200+ polarity of the 24V supply voltage must be set to direction “CLOSE” (A = 24 V, B = 0 V) using
the switch (4).
MAIN
S POWER
SERVICE CASE
POWER 24V
CHARGE
POWER 24V
ON
OFF
WINDOW
OPEN
FULL
ALARM
VENTILATION
LINBUS
ON
OFF
CLOSE
CURRENT
FUSE 24V
WINDOW
ST220
Mains socket
230V / 50 Hz
12
2
7
1
10
6
or
13
ON
X
GEZE
0V Zu
24V Zu
SIGNAL
LIN
9
11
A
B
S
L
14
8
3
4
5
A
B
S
L
1
Service case
2
MAINS POWER (mains connection mains fuse,
mains switch)
3
POWER 24 VDC ON / OFF switch
4
WINDOW OPEN / CLOSE switch (window/drive)
5
LIN-BUS ON/OFF switch (only for drives with
LIN-BUS)
6
Switch ALARM/VENTILATION
(ALARM: Alarm speed, VENTILATION:
Ventilation speed can be adjusted)
7
Connection for service terminal (parameter setting
unit) ST 220
8
Connection WINDOW (for single drive /
window)
9
Ammeter (for display of the current consump-
tion of the drive/window)
10
Mains connection cable
11
Drive connection cable – Service case
12
Service terminal ST 220
13
Connection cable ST 220 mini DIN
14
F 1200+ drive