F 1200+ window drive
23
Electrical connection
7.3 Connection
Carrying out electrical connection
X
Carry out connection to the 24V supply voltage in accordance with DIN VDE 0100-600.
X
Only connect the 24V system to a power supply with safety low voltage SELV.
X
Heed the specifications on the wiring diagram (see chapter 18.1 “Drive wiring diagram”).
X
Execute the cable type, line length and line cross-section in accordance with the technical specifications.
X
Always use wire-end ferrules for wire cores.
X
Insulate wires that are not used.
X
An on-site, 2-pole circuit breaker with locking option is to be used as a line-side disconnecting device, in
accordance with the permissible cable current load.
A
+24 V DC
(24V supply voltage)
B
GND
(24V supply voltage)
S
Signal (not occupied)
L
LIN (communication)
7.3.1 Connect the connecting cable of the drip loop
Prepare the cable of the drip loop
X
Combine each 2 wires (2 colours) of the total of 6 wires of the drip loop at both ends of the cable with one of
the enclosed twin wire end sleeves.
à
Make sure to use the
same wire colours
at both ends of the cable.
Bushing
Plug
green
brown
red
yellow
white
blue
A
B
L
green
brown
red
yellow
white
blue
A
B
L
Connecting the connecting cable
X
Connect the resulting 3 double wires of
the drip loop (1) to the cable clamp (2) at
the inputs A, B and L.
à
The clamp S remains unoccupied.
a
s
X
Unscrew screw (1) of the cover cap.
X
Remove the cover cap (2).