Back-lighting timing
Use the
or
button key to set the minimum duration of the
inactivity time of the user before the back-lighting is automatically
deactivated (the gap can be set from 10 to 180 seconds). This
parameter is only visible if the back-lighting is active. To confirm
your choice and move on to the next parameter, press the
button key within 30 seconds.
Back-lighting intensity
Use the
or
button key to choose how to manage the back-
lighting intensity (MAN = fixed value; SENS = light sensitive
sensor). This parameter is only visible if the back-lighting is active.
If the type of management is MAN, use the
or
button key to
choose the required percentage of light intensity (the gap can be
set from 30 to 100%).
If the type of management is SENS, use the
or
button key to
increase (+10%), decrease (-10%) or leave unaltered (0%) the
intensity value detected by the built-in light sensitive sensor. To
confirm your choice and move on to the next parameter, press the
button key within 30 seconds.
Outside temperature sensor
Use the
or
button key to set the function of the NTC
temperature sensor connected to the timed thermostat (OFF =
disabled; TEMP = enabled as a temperature probe; FLO = enabled
as an underfloor probe). To confirm your choice and move on to
the next parameter, press the
button key within 30 seconds.
Impact of the outside temperature sensor on the calculation
of the measured temperature
Use the
or
button key to set the weight (%) of the outside
temperature sensor for the calculation of the temperature
measured by the timed thermostat (value can be set from 10% to
100%, with steps of 10). The parameter is only displayed if the
NTC temperature sensor connected to the timed thermostat is
enabled as a temperature probe on the previous screen. To
confirm your choice and move on to the next parameter, press the
button key within 30 seconds.
16
USER INSTRUCTIONS