E 10
Alarm Code Alarm Cause Solution
Door motor can
not work!
(1)check DC 24V d
power supply indicator is lighted?
oor motor
(2)check connection point between the d
and the power board.
oor motor
(3)check connection point between micro switch of d
and touching flakes.
oor motor
Temperature and
Pressure do not
match!
Measure:temperature sensor resistance value(
)
1000+(Ambient temperature
*3.8)
Ω ≈
℃
(1)if measurement result is OK,check poor contact point between the sensor and the
control board.(2)if measurement result is No,replac the temperature sensor.
E 11
Vacuum process
failure!
E 12
(1)check the vacuum pump is working? Focus on checking start capacitor is broken?
(2)check the water filter in chamber is be blocked?details operation see Fig.6.4-17.
(3)
check the opened-solenoid valve(Ev1) ,drain-solenoid valve(Ev5) and vacuum-solenoid
valve(ev4),take out and clean s
pool.(judgment leakage method: mist of water drop on
silicone tube and hot) .
.
APPENDIX 10:Accessories
Page 57 of 58
11
Summary of Contents for JN-23
Page 1: ...EURO CERT 1128 0197 English JN 23 MODEL SteamSterilizer InstructionManual CLASS B and S ...
Page 4: ...Page 03 of 58 ...
Page 5: ...Page 04 of 58 ...
Page 7: ...Page 06 of 58 ...
Page 8: ...Page 07 of 58 ...
Page 10: ...Page 09 of 58 JN 23 overall space required ...
Page 12: ...Page 11 of 58 ...
Page 13: ...Page 12 of 58 ...
Page 14: ...Page 13 of 58 ...
Page 40: ...Page 39 of 58 ...
Page 41: ...Fig 6 2 1 Fig 6 2 2 Fig 6 2 3 Page 40 of 58 ...
Page 42: ...Fig 6 2 4 Fig 6 2 5 Fig 6 2 6 Chapter 4 3 2 Chapter 4 3 2 Page 41 of 58 ...
Page 43: ...6 2 1 Periodic Maintenance Page 42 of 58 ...
Page 44: ...6 3 Extraordinary Maintenance Page 43 of 58 ...
Page 51: ...Page 50 of 58 ...
Page 52: ...134 04min 15min 3 134 18min 15min 3 121 20min 15min 3 Page 51 of 58 ...
Page 53: ...Page 52 of 58 ...