Operation Procedure
(
1
)
Set the camera type & address, then connect camera with main controller.
(
2
)
Enter above interface.
(
3
)
Set “type”, “address” & “preset” in the camera tab. Normally, no need to set “baud
rate”.
(
4
)
After above setting, enter “tracking” tab.
(
5
)
Rotate & zoom the camera to a certain position. In the meantime, the mic loop light
of tracked unit is flashing.
(
6
)
After setting, click “Save” to save the tracking position. Then unit/preset will plus 1
automatically for another tracking point setting.
(
7
)
Click “Test” to check preset point.
8.6 Parameter setting.
Parameter setting can be saved as group in this menu. Groups can be loaded to the
current system.
There are 8 groups can be saved in one main controller. Each group included below
parameters: “Meet Mode”, “Tracking mode” “Speaking QTY”, “Time Off”, “Volume”,
“Capacity”.
Use “Restore to Preset”, to go back to default setting as below:
Meet Mode: FIFO
Tracking Mode: auto
Speaking QTY: 3
Time Off: 000
Volume: 24
Capacity: 020
Group Setup
Current Parameter
:
Meet Mode: FIFO
Tracking Mode:Auto
Speaking QTY
:
3
Time Off
:
003
Volume
:
21
Capacity
:
010
Save
Load
Restore to Preset
Exit
Notice:
a.There is no “Channel” in group.
b
.
Only those saved groups can be loaded, otherwise, system will prompt “group invalid”
c
.
Be careful about the system capacity when loading group or restore factory setting.
Modify system capacity according to the actual amount of units.
8.7 System Info
To check technical specification of main
controller.
8.8 Advanced setting
Interface of advanced setting.
8.8.1 Edit Address
System must be edited address before first used.
Description:
a Unit: address for the current applying unit.
.
b Channel: The channel for current applying unit. After finishing “edit address”, system
.
will enter this channel
Current Capacity: current system's capacity. System will keep the last capacity. If the total
number of edited address units is beyond last system capacity, system will modify the
current capacity accordingly.
①
All the units of the same channel will be controlled to enter “Edit Address” interface.
②
Set “unit” and “channel”, then wait for unit's address applying.
③
Press the on/off button on the units in order to obtain address.
Notice:
①
If there are units not in interface of “Edit Address” (could be because of different
channels), these units can be manually set to enter “Edit Address” according to
below unit menu instruction.
②
Chairman unit must be edited “001”, so that it's priority function can be carried out.
③
Try not to manually modify “unit” and “channel” after editing address started.
Otherwise, it may cause error.
Advanced Setup
Edit Address
Detect
Channel
Shift
Channel
Central
Controller
Code
Exit
Edit Address
Press Mic to Apply
...
Exit
Unit
:
001
Channel
: 04
Current Capacity
:010
Max. Capacity
:127
System Info
Exit
Hardware: 00
Software:02
Current Channel:03
Current Capacity:001
Max.Capacity:127