Gestton EG-7240 User Manual Download Page 2

Safety instruc ons

When using this electronic device, basic precau ons should always be taken,
 including the following:

1

   Read all instruc ons before using the product.

2

   Do not use this product near water (e.g., near a bathtub, washbowl, kitchen 

sink, in a wet basement or near a swimming pool etc).

3

   Use this device when you are sure that the controller has a stable base and it is 

fixed securely.

4

   This product, in combina on with loudspeakers and amplifier may be capable 

of producing sound levels that could cause permanent hearing loss. Do not 
operate for a long period of  me at a high volume level or at a level that is 
uncomfortable. If you experience any hearing loss or ringing in the ears, you 
should consult with otorhinolaryngologists.

5

   The product should be located away from heat sources such as radiators, heat 

vents, or other devices that produce heat.

6

   The product should be connected to a power supply that is described in the 

opera ng instruc ons or are marked on the product.

7

   Before the wiring always unplug equipment’s from main power supply.

8

   The power supply should be undamaged and never share an outlet or extension 

cord with other devices. Never leave device plugged in the outlet when it is not 
being used for a long period of  me.

9

   Care should be taken that objects do not fall into liquids and liquids would not 

be spilled on the device.

10

 Do not block any ven la on openings. Install in accordance with the 

manufacturer’s instruc on.

USER MANUAL | EG-7240 Digital Wireless Conference System

Safety instruc ons

11

  Do not defeat the safety purpose of the polarized or grounding-type plug. A 

polarized plug has two blades with one wider than the other. A grounding-type 
plug has two blades and a third grounding prong. The wide blade or the third 
prong are provided for your safety. If the provide plug does not fit into your 
outlet, consult an electrician for replacement of the obsolete outlet. 

12

  Protect the power cord from being walked on or pinched par cularly at plugs, 

convenience receptacles, and point where they exit from the apparatus. 

13

  Only use a achments/accessories specified by the manufacturer.

14

  Unplug this apparatus during lightning storms or when unused for long periods 

of  me.  

15

  The apparatus shall be connected to a main socket output with a protec ve 

earthing connec on. 

16

  The product should be serviced by qualified service personnel if :

 
       - The power supply or the plug has been damaged.
       - Objects have fallen into or liquid has been spilled on the product.
       - The product has been exposed to rain. 
       - The product has been dropped or the enclosure damaged. 
       - The display or main board damaged 

17

  There are some areas with high voltage inside, to reduce the risk of electric 

shock ,  do not remove cover of the controller or power supply. The cover 
should be removed by qualified personnel only. 

USER MANUAL | EG-7240 Digital Wireless Conference System

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

To reduce the risk of electric shock,do not remove screws,

No user-serviceable parts inside.Refer servicing to qualified

service personnel.To reduce the risk of fire,electric shock

or product damage,do not expose this apparatus to rain,

moisture,dripping or splashing and that no objects filled

with liquids,such as vases,shall be placed on the apparatus.

Summary of Contents for EG-7240

Page 1: ...X Y Digital Wireless Conference System EG 7240 USER MANUAL ...

Page 2: ...11 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provide plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 12 Protect the power co...

Page 3: ... comply with the Direc ve 2012 19 EU of the European Parliament on waste electrical finance the cost of treatment and recovery of electronic equipment WEEE in order to reduce the amount of WEEE that is being disposed of in land fill site All of our products are marked with the WEEE symbol this indicates that this product must NOT be disposed of with other waste Instead it is the user s responsibilit...

Page 4: ...then pull the antenna to about 45 angle Power supply AC110 220V To get the best communication the minimum installation height to the ground shall be 1m the minimum distance between launch antenna receiving antenna shall be 2m the minimum distance to wall shall be 1m Keep antennas away from interference such as computer digital equipment TV also big metal item Try to avoid putting barrier in betwee...

Page 5: ... 10 11 12 9 Product overview 7 Charger unit POWER SWITCH AC POWER SOCKET CHARGING OUTPUT POWER 6V IN Charger unit supports charging 40 microphone units at a time User should switch OFF the microphone units and connect the charging port of microphone units to the DC ports with supplied charging cable Charging time is approx 4 5 hours 8 Menu of Main Controller Main controller adopts capacitive touch...

Page 6: ...an speak in the same time 1 chairman 3 delegates Time Off Ÿ To turn off the unit compulsively by the set certain time 001 999 second 000 mean this function is disable Volume Ÿ To set the volume of main controller output Capacity Ÿ To limit the total amount of online units Ÿ When the unit address is beyond system capacity it can t connect to the system Ÿ For example when set system capacity is 3 sy...

Page 7: ...out the system capacity when loading group or restore factory setting Modify system capacity according to the actual amount of units 8 7 System Info To check technical specification of main controller 8 8 Advanced setting Interface of advanced setting 8 8 1 Edit Address System must be edited address before first used Description a Unit address for the current applying unit b Channel The channel fo...

Page 8: ...00 00 00 F5 Xx for Unit 00 for Full View More code Refer to Protocol Table Other Please select Operate EVI D70 YAAN PELCO D PELCO P Camera BRC Z330 Rotate Zoom Save Load Operate Direction Speed Unit 000 Address Preset Central Controller Code Conference Setup Camera Tracking Other Selection Meet Mode Tracking Mode Speaking QTY Time Off Volume Capacity Parameter Conference Setup Camera Tracking Othe...

Page 9: ...dress Manual Setup System Info Edit Address C u r r e n t S e t t i n g 00 000 CH Addr Press Mic to Apply 1 2 3 4 Edit Address Current Setting 00 000 CH Addr Fail Edit Address Current Setting CH Addr 00 000 Complete CONFIG ABNORMAL CH 00 Addr 000 Opera on Once unit is successfully edited address it will shows as picture System will go back to status interface when exiting edit address menu If fail...

Page 10: ...t admin 10 2 Meet Control Ÿ Virtual Saloon Allow user to draw the layout of the meeting table pattern the ID relates to the ID assigned to each microphone unit Ÿ Meet Setup User can configure the setup of the system via this panel including Meet mode Delegate QTY Tracking mode Time off Capacity Volume Ÿ Channel Manage Switch ON OFF the microphone operated on each channel 9 3 Second Screen This win...

Page 11: ...2 Parameters can be selected from SIGN IN SETUP and SECONDARY SCREEN menu accordingly 3 Press Start Sign in to kick off the process operator can see the process message from the PROCEDURE OF SIGN IN window and attendees will see the system message prompted on the display of each microphone unit connected Attendee should press the ENTER button on the microphone to finish the sign in 4 Operator can ...

Page 12: ... 18 4 Click Start at progress window can commence the voting immediately Voting options will be shown on the display of each microphone unit connected in this process Attendees can press YES NO ABST 1 2 3 4 5 button on their microphone units and pressing Enter to confirm their selection Voting data will collected to the system in real time basis operator can see the number of voted units and remai...

Page 13: ...ing then the proposal will be considered as a finished voting operator will not be able to re enter the voting process under this proposal but can only view the result of it But if operator press TERMINATE in the middle of this process then the process will be aborted and the proposal can be re selected to enter the voting process System specifica ons 11 System connection Main Controller camera TV ...

Page 14: ... system 1 Firstly check System Info in the main controller Check the value for channel current capacity Then manually set the unit as the same channel address to be current capacity 1 For example system channel 01 current capacity 30 then unit shall be set as channel 01 address 31 Details refer to 8 5 2 Re edit address for the whole system 1 Modify the capacity of system according to 7 4 2 Set Man...

Reviews: