NRS 140
Apply power to the unit.
The four indicator LEDs flash rapidly.
The LED “Power” lights up.
The test cycle takes about 3 sec.
NRS 140
Normal operation, electrode(s) submerged.
The four indicator LEDs are not illuminated.
The LED “Power” lights up.
Note
n
To analyse and eliminate malfunctions that may occur during the com missioning
procedure refer to section
“Malfunctions”
and
“System Malfunctions”
.
Commissioning
Operation
NRS 140
Press button briefly (1sec.).
The test mode is activated for about
10 sec. Be sure to press
button or within these 10 sec.
Note:
The safety circuit will be interrupted during the test
cycle.
Press button for 3 sec.
LED 1 flashes rapidly and remains
permanently illuminated after 3 sec.
A lowlevel alarm is simulated for electrode 1.
Test Cycle