7
NRG 16-41, -41.1; NRG 17-41, -41.1; NRG 19-41, 19-41.1
Type Approval
TÜV · SWB / SHWS · ..-403
TÜV · SWB / SHWS · ..-413
Service pressure
NRG 16-41, NRG 16-41.1
NRG 17-41, NRG 17-41.1
NRG 19-41, NRG 19-41.1
32 bar g at 238 °C
46 bar g at 260 °C
100 bar g at 311 °C
Connection
Screwed ¾", EN ISO 228-1
Materials
Terminal box: Die cast aluminium 3.2161 (G AlSi8Cu3)
Sheath: 1.4301 X5 CrNi18-10
Screwed union: S. S. 1.4571 (X6CrNiMoTi17-12-2)
Measuring electrode: S. S. 1.4401 (X5CrNiMo17-12-2)
Electrode insulation: PEEK
Lengths supplied
500 mm, 1000 mm, 1500 mm
Sensitivity of response
> 0.5
µ
S/cm at 25 °C
Supply voltage
18 – 36 V DC (coming from NRS 1-41, NRS 1-40.1, NRS 1-40.2)
Current consumption
35 mA
Fuse
Electronic thermal fuse T
max
= 85 °C
Hysteresis
-2 K
Electrode voltage
2 V
ss
Data exchange
CAN bus to DIN ISO 11898, CANopen Protocol
Indicators and adjustors
One 10-pole code switch for setting node ID and baud rate
Two LEDs “
P
rograM
running
”
Two LEDs “
c
an
bus
coMMunication
”
Electric connection
M 12 sensor plug, 5 poles, A-coded,
M 12 sensor socket, 5 poles, A-coded
Protection
IP 65 to DIN EN 60529
Max. admissible ambient temperature
70 °C
Weight
Approx. 2.5 kg
Technical Data
Summary of Contents for NRG 16-41
Page 27: ...27 For your Notes ...