18
In the event of back pressure, you must also
block off the drainage line downstream of the
equipment.
The screw plugs opposite the thermometer and
pressure gauge feature a hole. Through this, you
can let off pressure with the screw plugs.
Slacken one of the two screw plugs slightly.
You can now hear the medium diverting through the
hole. The display on the pressure gauge changes.
Once the pressure has fully dissipated, close the
screw plug.
Only commence work once the pressure gauge
displays zero pressure.
DANGER
If the equipment is used in contaminated
areas there is a risk of severe injuries or
death caused by harmful substances in or
on the equipment.
Only qualified personnel are allowed to
perform work on contaminated
equipment.
Always wear the protective clothing
prescribed for contaminated areas
when working on the equipment.
Make sure that the equipment is
completely decontaminated before
carrying out any service work.
Follow the pertinent instructions for
handling the hazardous substances in
question.
Attention!
Frost damage may occur when the
installation is shut down.
Drain the equipment if ambient
temperatures below 0 °C (frost) are to
be expected.
If there is a risk of freezing, you must
completely drain the equipment after
operation.
To do this, you can install a drainage valve
in the water pocket.
To drain the equipment, proceed as follows:
Make sure that medium exiting the system is
caught.
Unscrew the adjuster at the bottom out of the
body.
Medium exits the system.
Wait until the equipment has drained fully.
Remove the sealing ring from the hole.
Dispose of the sealing ring in accordance with
regulations at the location of use.
Insert a new sealing ring of the same type in the
hole.
Lubricate all threads and the contact surfaces of
nuts and bolts with temperature-resistant
lubricant.
The lubricant must have the same properties as
OKS
®
217.
Screw the adjuster into the body.
Using the adjuster, tighten the size 32 hex nut
to a torque of 80 Nm.
Removing external dirt deposits
To remove dirt deposits rinse the equipment
with fresh water and wipe it with a clean, lint-
free cloth.
To remove any persistent residues use a
cleaning agent that is suitable for the material
and carefully wipe the equipment with a clean,
lint-free cloth.
Maintaining the equipment
The equipment does not require any particular
maintenance.
Summary of Contents for Gestramat CW 41
Page 21: ...21 Spare parts for CW 41 4 ...
Page 34: ...34 MCW 41 and MCW 41 4 ...
Page 38: ...38 ...
Page 39: ...39 ...