Gespasa GK-7PLUS Instruction Manual Download Page 6

 

GK-7PLUS CONTROLLER INSTRUCTION MANUAL  

 

2. USER MODE 

The user mode is the mode that the kit allows making a supply to an authorized user. 

Depending on the kit configuration, it will be necessary to make some or every one of the following steps so 
that a supply is completed: 

 

Step 1. User identification 

According to the kit configuration, this step is made through the following options: 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Identification by key: 

 
 
- If the kit has been configured for 
user identification by key, the display 
will show the following message as 
well as the date and the hour: 
 

PASS IDENTIFIER 

 

The user must put the identification 
key in its place and keep it in this 
position until the kit recognizes it, 
making a brief 'beep'. 
 
- If the identifier is not one of the 
authorized identifiers, the kit will show 
the following message during some 
seconds: 

IDENTIFIER 

NOT VALID 

and after this time it will go back to 
the initial display. 
 
- If, on the contrary, the identifier is 
known as an authorized identifier, the 
kit will show the following message: 

 

TYPE PERSONAL CODE: 

 
The user must type its PIN or personal 
code, composed of 4 digits, and 
confirm with the key <OK>.  
 
If the typed code is not correct, the kit 
will ask for the code typing again. If 
the user types an incorrect code three 
times, the user will have to pass again 
the identifier. 
  
If the identification has been correct, 
the kit will pass to the following step. 

Identification by PIN: 

 
 
- If the kit has been configured for 
user identification by PIN code, the 
display will show the following 
message as well as the date and the 
hour: 
 

PRESS A KEY 

 
- Pressing any key, it will appear the 
following message on the display: 
 

TYPE PERSONAL CODE: 

 
The user must type its PIN or personal 
code, composed of 4 digits, and 
confirm with the key <OK>.  
 
If the typed code is not correct, the kit 
will ask for the code typing again. If 
the user types an incorrect code three 
times, the user will have to pass again 
the identifier. 
  
If the identification has been correct, 
the kit will pass to the following step. 
 

Without user identification 

 
 
- If the kit is configured to work 
without user identification, this step 
will not be made. The position starting 
of the kit will be that described in the 
step 2. 

Summary of Contents for GK-7PLUS

Page 1: ...PLUS CONSUMPTION CONTROLLER SUPERVISOR AND USER MODE INSTRUCTION MANUAL Unit 7 Swan Business Centre Osier Way Buckingham MK18 1TB Email sales bellflowsystems co uk https www bellflowsystems co uk 44 0...

Page 2: ...GK 7PLUS CONTROLLER INSTRUCTION MANUAL 2...

Page 3: ...OR Mode SUPERVISOR Menu CONFIGURATION 14 3 2 5 1 1 SUPERVISOR mode SUPERVISOR MENU CONFIGURATION CONSOLE 14 3 2 5 1 2 SUPERVISOR mode SUPERVISOR MENU CONFIGURATION TANKS 15 3 2 5 1 3 SUPERVISOR mode S...

Page 4: ...family controllers and are designed to automatically communicate M2M with the DieselPlus application The GK 7PLUS controllers are not able to work in autonomous way they need the DieselPlus applicati...

Page 5: ...it is possible a value with a decimal you have to press the key as a decimal During the data typing you have to use the key to delete the last typed character The key OK will be used to confirm the ty...

Page 6: ...he following message TYPE PERSONAL CODE The user must type its PIN or personal code composed of 4 digits and confirm with the key OK If the typed code is not correct the kit will ask for the code typi...

Page 7: ...econds IDENTIFIER NOT VALID and after this time the kit will ask for the identifier again This can be repeated up to three times and then the kit will reinitiate the service authorization process If t...

Page 8: ...he display will show the following message SERVICE AUTHORIZED The user has to take the nozzle off Then the pump motor will start and the display will change showing the supply volume through big size...

Page 9: ...his PIN code depending on the identification mode and ask for the ticket printing The value in seconds of this time is that configured in the parameter ticket request seconds If the user lets this tim...

Page 10: ...ted to the SUPERVISOR 3 2 SUPERVISOR mode menu To go into the SUPERVISOR mode first you have to press the key OK without dropping it press the key at the same time Once the SUPERVISOR PIN 0220 is corr...

Page 11: ...between the pulses and the volume Independently of this system the kit has also built in the traditional system of the whole factor as it will be described below Procedure Accepting the CALIBRATION o...

Page 12: ...is not enabled in the system will point out where the list will be displayed If the printer is enabled the list will be printed If on the contrary it is not enabled the configuration will be only show...

Page 13: ...EQUEST SECONDS ADDRESS HIDING 300 ml TAX DECIMALS PRICE DECIMALS TOTAL DECIMALS HOSE SELECTOR TANKS NAME SALE PRICE TAX HOSES GENERATOR TYPE RESOLUTION FACTOR FACTOR PROTECTION TANK W O PULSES MAXIMUM...

Page 14: ...assigned an identification key By numeric code where each vehicle has assigned a numeric code among 1 and 99 999 PREDETERMINATION This parameter allows or not enabling the predetermination preset in t...

Page 15: ...r to the tanks that have the products that the installation can supply These parameters are NAME It is the product name This name will appear in the ticket at the end of the supply if it has a printer...

Page 16: ...service MAXIMUM QUANTITY It is the maximum volume in litres or the volume unit with which is working that the kit will allow supplying in one go Once this amount is achieved the kit will finish the s...

Page 17: ...given by DieselPlus DNS1 Preferred DNS Server DNS2 Alternative DNS Server The values of the SERVER LOCAL AND REMOTE PORT only can be modified from the DieselPlus application 3 2 5 2 SUPERVISOR mode S...

Page 18: ...llowing USERS All the authorized users will be eliminated VEHICLES All the authorized vehicles will be eliminated SERVICES All the stored services will be eliminated CONFIGURATION It will be loaded a...

Page 19: ...shaft 3 Remove the finished roll and put the new one 4 Put the beginning of the new roll by the lower printer groove You have to make a clean and perpendicular cut on the paper 5 The printer has an au...

Page 20: ...GK 7 CONTROLLER Language Spanish Printer Not enabled L1 Printer GK 7 CONTROLLER L2 Printer L3 Printer L4 Printer L5 Printer Ticket requ Seconds 60 Address 1 Hiding 300 ml YES TAX decimals 0 Price dec...

Page 21: ...SIM card must have enabled the GPRS data transmission and its PIN deactivated HOW TO INSERT OR REPLACE THE SIM CARD OF THE CONTROLLER 1 In the controller back disconnect the connectors 2 Unscrew the 4...

Page 22: ...de SUPERVISOR MENU CONFIGURATION GPRS according to the information given by the mobile phone operator of the SIM card 3 Restart the GK 7PLUS controller or the kit Once the GK 7PLUS controller or the k...

Page 23: ...e approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89 336 EC and it has been manufactured according to the below harmonized regulations...

Reviews: