GK-7PLUS CONTROLLER INSTRUCTION MANUAL  

 

11 

3.2.2. SUPERVISOR mode / REGULARIZATION 

This option allows adjusting the level shown by the kit to the real level that there is in the tank. Because of 
some differences in the accuracy of some instruments, which are used to count the entered and supplied 
liquid, it is possible that there can be some imbalances between the shown value by the kit and the 
measured value. This option allows making a "regularization" of this level. 

Once selected one of the available tanks, the display will show: 
 

REGULARIZ. LIQUID X 

CURRENT QUANTITY: 

The kit will wait that the current litre (or the volume unit with which is working) number is typed. Once the 
quantity is typed and confirmed with the key <OK>, the kit will have this value as the current tank level. 

 

3.2.3. SUPERVISOR mode / CALIBRATION 

This option allows the meter calibration. The kit has built in an automatic electronic calibration process by 
means of passing a known amount of liquid through the meter; while the kit "counts" the pulses generated 
by the meter. Once the liquid has passed, it will be indicated to the kit the transferred amount with which the 
kit can calculate the relation that there is between the pulses and the volume. Independently of this system, 
the kit has also built in the traditional system of the whole factor, as it will be described below. 

Procedure:

 Accepting the CALIBRATION option, after putting the pointer and pressing the key <OK>, the kit 

will start the pump (independently of the nozzle position) and will show the following message on the 
display: 

SUPPLY KNOWN AMOUNT 

AND PRESS OK 

In this point, fill a recipient with a known volume. The best option is to use a homologated dekalitre. Once 
filled, press <OK>, and the kit will stop the pump and show the following message: 

TYPE SUPPLIED 

AMOUNT: 

where the supplied volume must be typed. Remember that there is the possibility to type in decimals. 
Consult the section 1. General Instructions to use the keypad. 

Once typed this amount and confirmed with the key <OK>, the display will show the following message: 

NEW FACTOR    FFFFFF 
 
OK   = ACCEPT 
EXIT = REJECT 

where FFFFFF is the new calculated factor of calibration and represents the number of hundred thousandth 
of litres (or the volume unit with which is working) that the count will be increased by each received pulse, 
having the option to accept the new value through the key <OK> or reject it through the key <EXIT>. 

If the kit has not noticed any pulse or the typed quantity has been equal to 0, it will not be possible to make 
the calculation and the shown message will be: 

Summary of Contents for GK-7PLUS

Page 1: ...PLUS CONSUMPTION CONTROLLER SUPERVISOR AND USER MODE INSTRUCTION MANUAL Unit 7 Swan Business Centre Osier Way Buckingham MK18 1TB Email sales bellflowsystems co uk https www bellflowsystems co uk 44 0...

Page 2: ...GK 7PLUS CONTROLLER INSTRUCTION MANUAL 2...

Page 3: ...OR Mode SUPERVISOR Menu CONFIGURATION 14 3 2 5 1 1 SUPERVISOR mode SUPERVISOR MENU CONFIGURATION CONSOLE 14 3 2 5 1 2 SUPERVISOR mode SUPERVISOR MENU CONFIGURATION TANKS 15 3 2 5 1 3 SUPERVISOR mode S...

Page 4: ...family controllers and are designed to automatically communicate M2M with the DieselPlus application The GK 7PLUS controllers are not able to work in autonomous way they need the DieselPlus applicati...

Page 5: ...it is possible a value with a decimal you have to press the key as a decimal During the data typing you have to use the key to delete the last typed character The key OK will be used to confirm the ty...

Page 6: ...he following message TYPE PERSONAL CODE The user must type its PIN or personal code composed of 4 digits and confirm with the key OK If the typed code is not correct the kit will ask for the code typi...

Page 7: ...econds IDENTIFIER NOT VALID and after this time the kit will ask for the identifier again This can be repeated up to three times and then the kit will reinitiate the service authorization process If t...

Page 8: ...he display will show the following message SERVICE AUTHORIZED The user has to take the nozzle off Then the pump motor will start and the display will change showing the supply volume through big size...

Page 9: ...his PIN code depending on the identification mode and ask for the ticket printing The value in seconds of this time is that configured in the parameter ticket request seconds If the user lets this tim...

Page 10: ...ted to the SUPERVISOR 3 2 SUPERVISOR mode menu To go into the SUPERVISOR mode first you have to press the key OK without dropping it press the key at the same time Once the SUPERVISOR PIN 0220 is corr...

Page 11: ...between the pulses and the volume Independently of this system the kit has also built in the traditional system of the whole factor as it will be described below Procedure Accepting the CALIBRATION o...

Page 12: ...is not enabled in the system will point out where the list will be displayed If the printer is enabled the list will be printed If on the contrary it is not enabled the configuration will be only show...

Page 13: ...EQUEST SECONDS ADDRESS HIDING 300 ml TAX DECIMALS PRICE DECIMALS TOTAL DECIMALS HOSE SELECTOR TANKS NAME SALE PRICE TAX HOSES GENERATOR TYPE RESOLUTION FACTOR FACTOR PROTECTION TANK W O PULSES MAXIMUM...

Page 14: ...assigned an identification key By numeric code where each vehicle has assigned a numeric code among 1 and 99 999 PREDETERMINATION This parameter allows or not enabling the predetermination preset in t...

Page 15: ...r to the tanks that have the products that the installation can supply These parameters are NAME It is the product name This name will appear in the ticket at the end of the supply if it has a printer...

Page 16: ...service MAXIMUM QUANTITY It is the maximum volume in litres or the volume unit with which is working that the kit will allow supplying in one go Once this amount is achieved the kit will finish the s...

Page 17: ...given by DieselPlus DNS1 Preferred DNS Server DNS2 Alternative DNS Server The values of the SERVER LOCAL AND REMOTE PORT only can be modified from the DieselPlus application 3 2 5 2 SUPERVISOR mode S...

Page 18: ...llowing USERS All the authorized users will be eliminated VEHICLES All the authorized vehicles will be eliminated SERVICES All the stored services will be eliminated CONFIGURATION It will be loaded a...

Page 19: ...shaft 3 Remove the finished roll and put the new one 4 Put the beginning of the new roll by the lower printer groove You have to make a clean and perpendicular cut on the paper 5 The printer has an au...

Page 20: ...GK 7 CONTROLLER Language Spanish Printer Not enabled L1 Printer GK 7 CONTROLLER L2 Printer L3 Printer L4 Printer L5 Printer Ticket requ Seconds 60 Address 1 Hiding 300 ml YES TAX decimals 0 Price dec...

Page 21: ...SIM card must have enabled the GPRS data transmission and its PIN deactivated HOW TO INSERT OR REPLACE THE SIM CARD OF THE CONTROLLER 1 In the controller back disconnect the connectors 2 Unscrew the 4...

Page 22: ...de SUPERVISOR MENU CONFIGURATION GPRS according to the information given by the mobile phone operator of the SIM card 3 Restart the GK 7PLUS controller or the kit Once the GK 7PLUS controller or the k...

Page 23: ...e approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89 336 EC and it has been manufactured according to the below harmonized regulations...

Reviews: