5 Technical data
Operating pressure (p
B
):
1,5 – 7,0 bar (p
Bmax
= 15,0 bar)
Working pressure (p
A
):
400 bar (max. constant operating pressure)
Hydr. Test pressure (p
prüf
):
600 bar (test operating)
Device circuit points:
Screw in unit:
shipment
Operating pressure:
compressed air connection
∅
9 mm
Weight:
empty:
119 kg
Measurements:
Height:
1350 mm
Length:
700 mm
Width:
600 mm
Tank capacity:
4 l (dm³)
Capacity and air consumption:
0,53 m³/min for 6 bar compressed air ≡ 0,37 dm³/min for 1000 bar
1,23 m³/min for 6 bar compressed air ≡ 0,90 dm³/min for 0 bar
6 Service and self-help
If as described in point
2.1.
13 operating pressure on indicator
A
is not steady but drops, there is
leaking on the pump or pressure control valve
E
is not completely closed.
This is normally caused by wear of gaskets on the pump. Gaskets may be changed.
Maintenance of GERUTEST through manufacturer