![German pool GKH-24 Operating Instructions Manual Download Page 59](http://html1.mh-extra.com/html/german-pool/gkh-24/gkh-24_operating-instructions-manual_2216558059.webp)
(
3
)
Connect the power supply cable to the “L, N”
terminals and
Caution:
Take great care when carrying out the
following connections, so as to avoid
malfunction of the air-conditioning unit
because of electromagnetic interference.
(1) The signal line of the wire controller must
be separated from the power line and the
connecting line between the indoor unit and
the outdoor unit.
(2) In case the unit is installed in a place
vulnerable by electromagnetic interference, it
is better to use shielded cable or
double-twisted cable as the signal line of the
wire controller.
the grounding screw.
(
4
)
Use cable fastener to bundle and fix the cable.
2. Air-conditioning unit with 3-phase power supply
(
1
)
Remove the front-side panel of the outdoor unit.
(
2
)
Attach rubber ring to the cable-cross hole of the
outdoor unit.
(
3
)
Pass the cable though rubber ring.
(
4
)
Connect the power cable to the terminal and
earthing screws marked “L1, L2, L3 & N”.
(
5
)
Use cable fastener to bundle and fix the cable.
1
1
.5 Products Electric Installation
Wiring layout
☆
Installation should be conducted by National Wiring Regulation.
☆
The rated voltage and exclusive power supply must be adopted for the air conditioners.
☆
The power cable should be reliable and fixed, in order to avoid the wiring terminal be suffered
from force. And do not drag the power cable forcibly.
☆
The wire diameter of power cable should be large enough, if power cable and connection wire
be damaged, it should be replaced by the exclusive cable.
☆
All electric installation must be done by professional personnel according to local law,
regulation and this manual.
☆
It should be reliably earthed, and it should be connected to the special earth device, the installation
work should be operated by the professional.
☆
The creepage protect switch and air switch must be installed.
Air switch should have the thermal dropout and magnetic dropout function, in order to avoid the
56
Summary of Contents for GKH-24
Page 2: ......
Page 4: ...1 1 Names and functions of parts indoor unit outdoor unit GKH 24 GKH 24 EXT...
Page 5: ...2 indoor unit outdoor unit GKH 36 GKH 48 GKH 36 EXT GKH 48 EXT...
Page 23: ...TIMER operation procedure 20...
Page 25: ...How to inser t batteries 22...
Page 37: ...7 Optimum operation 34...
Page 39: ...The following are not troubles 36...
Page 40: ...9 Installation notes This should be done by professional 37...
Page 41: ...10 Care and maintenance Please cut off the power supply after you used the air conditioner 38...
Page 66: ......
Page 67: ...GKH 24 GKH 48 GKH 36...