4
)
Put the screw through the loop of the single wire and fix the loop at the terminal board.
2. Connection of multiple twisted wires
(
1
)
Use wire stripper to strip the insulation layer (10mm long) from the end of the multiple
twisted wires.
(
2
)
Remove the screw at the terminal board of the air-conditioning unit.
(
3
)
Use crimping pliers to connect a terminal (matching the size of the screw) at the end of the
multiple twisted wires.
(
4
)
Put the screw through the terminal of the multiple twisted wires and fix the terminal at the
terminal board.
Warning:
If the power supply flexible line or the signal line of the equipment is damaged, only use special
flexible line to replace it.
1
、
Before connecting lines, read the voltages of the relevant parts on the nameplate. Then carry out
line connection according to the schematic diagram.
2
、
The air-conditioning unit shall have special power supply line which shall be equipped with
electricity leakage switch and air switch, so as to deal with overload conditions.
3
、
The air-conditioning unit must have grounding to avoid hazard owing to insulation failure.
4
、
All fitting lines must use crimp terminals or single wire. If multiple twisted wires are connected
to terminal board, arc may arise.
5
、
All line connections must conform to the schematic diagram of lines. Wrong connection may
cause abnormal operation or damage of the air-conditioning unit.
6
、
Do not let any cable contact the refrigerant pipe, the compressor and moving parts such as fan.
7
、
Do not change the internal line connections inside the air-conditioning unit. The manufacturer
shall not be liable for any loss or abnormal operation arising from wrong line connections.
8
、
shall not be liable for any loss or abnormal operation arising from wrong line connections.
55
Connection Of the Power Cable
1. Air-conditioning unit with single-phase power supply
(
1
)
Remove the front-side panel of the outdoor unit.
(
2
)
Pass the cable though rubber ring.
Summary of Contents for GKH-24
Page 2: ......
Page 4: ...1 1 Names and functions of parts indoor unit outdoor unit GKH 24 GKH 24 EXT...
Page 5: ...2 indoor unit outdoor unit GKH 36 GKH 48 GKH 36 EXT GKH 48 EXT...
Page 23: ...TIMER operation procedure 20...
Page 25: ...How to inser t batteries 22...
Page 37: ...7 Optimum operation 34...
Page 39: ...The following are not troubles 36...
Page 40: ...9 Installation notes This should be done by professional 37...
Page 41: ...10 Care and maintenance Please cut off the power supply after you used the air conditioner 38...
Page 66: ......
Page 67: ...GKH 24 GKH 48 GKH 36...