![German pool GKH-24 Operating Instructions Manual Download Page 56](http://html1.mh-extra.com/html/german-pool/gkh-24/gkh-24_operating-instructions-manual_2216558056.webp)
Caution:
(
1
)
Do not wrap the protective tape too tight, otherwise the efficiency of thermal insulation
may be decreased. Ensure that the condensate drainage flexible tube is separate from the
bundled pipes.
(
2
)
After the protective work is completed and the pipes are wrapped, use seal material to
block the hole in the wall, so as to prevent rain and wind from entering the room.
G
、
Position and Method of Installing Wire Controller
1
、
First select an installation position. According to the size of the communication line of the
wire controller, leave a recess or a embedded wire hole to bury the communication line.
2
、
If the communication line between the wire controller (85
×
85
×
16) and the indoor unit is
surface-mounted, use 1# PVC pipe and make matching recess in the wall (refer to Figure 6);
If concealed installation is adopted, 1# PVC pipe can be used (Refer to Figure 7).
3
、
No matter if surface mounting or concealed mounting is selected, it is required to drill 2
holes (in the same level) which distance shall be the same as the distance (60mm) of
installation holes in the bottom plate of the wire controller. Then insert a wood plug into
each hole. Fix the bottom plate of the wire controller to the wall by using the two holes.
Plug the communication line onto the control panel. Lastly install the panel of the wire
controller.
Caution:
1.During the installation of the bottom plate of the wire controller, pay attention to the
direction of the bottom plate. The plate’s side with two notches must be at the lower position, and
otherwise the panel of the wire controller cannot be correctly installed.
2
3
4
1
PVC管
Fig 6 Surface Mounting of Cable
Fig 7 Concealed mounting of Cable Fig 8 Schematic Diagram of Installation
PVC Pipe
53
Summary of Contents for GKH-24
Page 2: ......
Page 4: ...1 1 Names and functions of parts indoor unit outdoor unit GKH 24 GKH 24 EXT...
Page 5: ...2 indoor unit outdoor unit GKH 36 GKH 48 GKH 36 EXT GKH 48 EXT...
Page 23: ...TIMER operation procedure 20...
Page 25: ...How to inser t batteries 22...
Page 37: ...7 Optimum operation 34...
Page 39: ...The following are not troubles 36...
Page 40: ...9 Installation notes This should be done by professional 37...
Page 41: ...10 Care and maintenance Please cut off the power supply after you used the air conditioner 38...
Page 66: ......