P.15
P.14
Declaration of conformity
This appliance complies with the following European Directives:
•
2014/35/EU regarding “low voltage”
•
2014/30/EU regarding “electromagnetic disturbances”
•
Regulation (EC) N° 1935/2004 regarding “materials in contact with food”
•
The above directives comply with 93/68/EEC regarding CE marking.
•
The manufacturer declares that the oven is built using certified materials and requires the
appliance to be installed in accordance with the standards currently in force. This appliance must
be used by a trained person for domestic purposes only.
•
Connect the wires as indicated in the image above, using the brass links provided where
necessary.
•
The earthing (yellow/green) conductor must always be 10 mm longer than the line conductors.
•
Care must be taken to ensure that the temperature of the mains supply cable does not exceed
50°C.
•
If the mains supply cable is damaged, then it must be replaced by an appropriate replacement
which can be obtained from the manufacturer.
Caution!
The power supply should have a safety switch to cut off the power in time in case
of an emergency. Before connecting the power cord, be sure to read the label and
connection diagrams carefully.
Electrical Connections
Electrical Connections
Installation Guidelines
•
Circuit requirement: single-phase AC power supply (220V - 240V ~ 50/60 Hz).
•
Drawings below shows the lid of the connection box.
•
Before connecting the appliance, make sure that the supply voltage marked on the rating plate
corresponds with your mains supply voltage.
•
Power cord should be tightened safely.
WARNING: THIS APPLIANCE MUST BE EARTHED.
This appliance should be wired into a 10A double pole switched fused spur outlet, having 3 mm
contact separation and placed in an easily accessible position adjacent to the appliance. The spur
outlet must still be accessible even when your oven is located in its housing.
•
To connect the oven power cord, remove the cover on the
terminal block, in order to gain access to the contacts inside.
Make the connection, securing the cord in place with the cable
clamp provided and then immediately close the terminal block
cover again.
PE
N
L
N
L
Caution! In the event of any connection the safety
wire must be connected to the PE terminal
CONNECTION DIAGRAM
Caution! Voltage of heating elements 220V~240V
For 220V-240V earthed one
phase connect on: Brown wire
connect to L and blue wire
connect to N, safety wire
(Yellowgreen) connect to
LIVE
BROWN
BLUE
YELLOW/GREEN
MAINS
POWER
SUPPLY
POWER CORD
L
EARTH
G
NEUTRAL
N
Summary of Contents for EVB-120
Page 19: ...P 37 P 36 38 42 43 44 48 50 57 61 64 66 67...
Page 20: ...P 39 P 38 85 4mm 85 220 240V 13A...
Page 21: ...P 41 P 40 15kg 5 10 20 40 10...
Page 24: ...P 47 P 46 45 50mm 515mm 40 50mm 80cm 515mm A A...
Page 27: ...P 53 P 52 30 40 50 250 50 250 150 0 100 200 50 250 150 0 100 200...
Page 28: ...P 55 P 54 4 150 150 150 5 250 200 10 10...
Page 32: ...P 63 P 62 220V 25W 300 G9 A B B A B a b c B A...
Page 33: ...P 65 P 64 1 2 3 4 2 5 10 6 7 8...