26
Chapter 6:
Operation
Power-Up
When- the GSx
plus
is turned on, the following sequence occurs.
1
A short beep sounds, the Power light comes on, and the RUN CONT
and RUN SINGLE lights blink.
2
As the GSx
plus
performs self-check tests, the lights over the RUN keys
flash, and one additional beep sounds.
3
When the self-check is complete, the lights blink and one beep sounds.
4
The plotter beeps and goes off-line. Only the Power light remains on.
This is the initial setting at power-up.
Note: Rapid, continuous beeping and flashing lights may signal a self-check
error. See the "Error Conditions" section for more information.
Front Panel
The GSx
plus
front panel keys shown
below are used to perform all of the
following operations:
♦
Position the carriage and
material.
♦
Put the plotter on-line for
drawing, cutting, and pouncing.
♦
Select single or continuous job processing.
♦
Initialize the knife tool.
♦
Access diagnostic modes, as needed. See the
Special Diagnostics
and
Error Conditions
sections for more information.
♦
A further explanation of key functions and several test exercises follow.