Command = SWITCH_BINARY_SET,
Value = 0xFF]
Off : [Command Class = COMMAND_CLASS_SWITCH_BINARY,
Command = SWITCH_BINARY_SET,
Value = 0x00]
3-2 MULTILEVEL_SWITCH_SET
The dimmer module 3 (endpoint3) will change their level when it is controlled by
the Controller.
For example :
On : [Command Class = COMMAND_CLASS_SWITCH_MULTILEVEL,
Command = SWITCH_MULTILEVEL_SET,
Value = 0x01 ~ 0x63]
Off : [Command Class = COMMAND_CLASS_SWITCH_MULTILEVEL,
Command = SWITCH_MULTILEVEL_SET,
Value = 0x00]
Z-Wave’s Groups (Association Command Class Version 2)
The Switch can be set to send reports to control associated Z-Wave devices. It
supports 9 association groups in which every group has two support nodes.
Group1 is Lifeline support DEVICE_RESET_LOCALLY_NOTIFICATION and
CENTRAL_SCENE_NOTIFICATION.
Group2 and Group7 which correspond to relay modules 1 and 2 support
COMMAND_CLASS_SWITCH_BINARY. The relay modules 1 and 2 correspond to
endpoints 1 and 6. The device type of endpoints 1 and 6 is POWER SWITCH
BINARY.
Group4 and Group9 which correspond to dimmer module 3 and 4 support
COMMAND_CLASS_SWITCH_MULTILEVEL. The dimmer modules 3 and 4
correspond to endpoints 3 and 8. The device type of endpoints 3 and 8 is POWER
SWITCH MULTILEVEL.
Group3
、
5
、
6
、
8 which correspond to smart buttons
②
、
④
、
⑥
、
⑧
support
COMMAND_CLASS_CENTRAL_SCENE. The smart buttons
②
、
④
、
⑥
、
⑧
correspond to endpoints 2
、
4
、
5
、
7. The device type of endpoints 1 and 6 are BASIC
WALL CONTROLLER.
Mapping to Association groups on the root device
Root device
Endpoint 1
Endpoint 2
Endpoint 3
Endpoint 4
Group1 :
Lifeline
Group1 :
Lifeline
Group1 :
Lifeline
Group1 :
Lifeline
Group1 :
Lifeline
Group2 :
Switch_Binary_
Set from
Endpoint 1
Group2 :
Switch_Binary_
Set
Group2 :
Basic_Set
Group2 :
Switch_Multilev
el_Set
Group2 :
Basic_Set
Group3 :
7