Gerber Technology GPS-2000 Manual Download Page 16

FCC

 Interference Statement

This equipment has been tested to comply with the limits for a Class B digital device, pursuant

to Part 15 of the FCC Rules. 

These limits are designed to provide reasonable protection against harmful interference in a 

residential installation. 

This equipment generates, uses and can radiate radio frequency energy and, if not installed 

and used in accordance with the instructions, may cause harmful interference to radio commu-

nications. 

However, there is no guarantee that interference will not occur in a particular installation. 

If this equipment does cause harmful interference to radio or television reception, which

can be determined by turning the equipment off and on, the user is encouraged to try to cor-

rect the interference by one of the following measures:

• 

Reorient or relocate the receiving antenna.

• 

Increase the separation between the equipment and receiver.

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is 

connected.

• 

Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 of the FCC Rules. Operation is subject

to the following two conditions:

(1) This device may not cause harmful interference, and

(2) This device must accept any interference received, including interference that may cause 

undesired operation.

FCC Caution: Any changes or modifications not expressly approved by the party responsible 

for compliance could void the user's authority to operate this equipment.

This transmitter must not be co-located or operating in conjunction with any other antenna or

transmitter.

16

Summary of Contents for GPS-2000

Page 1: ...enu allows remote operation of the unit and connected load Remote control of Dimmer Relay modules are possible with other manufacturer s wireless Controller as well GPS 2000 is designed to act as a re...

Page 2: ...light will flash one time when enter exclude mode 2 Press the middle button button three times within 2 seconds will enter exclusion mode 3 Node ID will get excluded Reset 1 Press the middle button bu...

Page 3: ...ve Controller LED light Indication To distinguish which module is in use you can view the LED light for identification State Type LED Indication Relay module The LED or will change color from blue to...

Page 4: ...buttons are smart buttons which can send central scene command to group 1 and Basic_Set command to group 3 5 6 or 8 Programming 1 Controlling relay module by Z Wave command The relay module will resp...

Page 5: ...t 0x00 Command Class COMMAND_CLASS_BASIC Command BASIC_REPORT Value 0x00 or 0xFF 2 Controlling dimmer module by Z Wave command The dimmer will respond to BASIC_SET and MULTILEVEL_SWITCH_SET commands t...

Page 6: ...dpoint 0x08 or 0x03 Command Class COMMAND_CLASS_BASIC Command BASIC_GET Basic Report Command Command Class COMMAND CLASS MULTI CHANNEL MULTI CHANNEL CMD ENCAP Source endpoint 0x08 or 0x03 Destination...

Page 7: ...oup7 which correspond to relay modules 1 and 2 support COMMAND_CLASS_SWITCH_BINARY The relay modules 1 and 2 correspond to endpoints 1 and 6 The device type of endpoints 1 and 6 is POWER SWITCH BINARY...

Page 8: ...2 Basic_Set Group2 Switch_Binary_ Set Group2 Basic_Set Group2 Switch_Multilev el_Set Multi Channel Command Class information of endpoints Root Device Device type POWER_SWITCH_BINARY Supported Command...

Page 9: ...NTRAL_SCENE COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION COMMAND_CLASS_SUPERVISION COMMAND_CLASS_SECURITY COMMAND_CLASS_SECURITY_2 Controlled Co...

Page 10: ...MULTI_CHANNEL_ASSOCIATION COMMAND_CLASS_SUPERVISION COMMAND_CLASS_SECURITY COMMAND_CLASS_SECURITY_2 Controlled Command Classes COMMAND_CLASS_BASIC Description When one short press on smart button it w...

Page 11: ...OMMAND_CLASS_SECURITY COMMAND_CLASS_SECURITY_2 Controlled Command Classes COMMAND_CLASS_SWITCH_MULTILEVEL Description When the level of dimmer module 2 is changed and achieved the desired level it wil...

Page 12: ...mum 2 Nodes 3 1 Pressing button to switch On Off Relay Button correspond to relay1 and button correspond to relay2 When the relay is off shortly pressing the assigned button will turn it on and send B...

Page 13: ...se button after a long pressing Command Class COMMAND CLASS MULTI CHANNEL MULTI CHANNEL CMD ENCAP Source endpoint 0x03 or 0x08 Destination endpoint 0x01 send to correspond grouping nodes Command Class...

Page 14: ...o improve a function if needed Command Classes The GPS 2000 supports Command Classes including Command Class Version Required Security Class Association 2 Highest granted Security Class Association Gr...

Page 15: ...Operating Temperature 0 C 40 C Frequency Range 868 4MHz 869 85MHz EU GPS 2000 1 908 4MHz 916 0MHz US GPS 2000 2 922 927MHz Taiwan Japan GPS 2000 3 916MHz Israel GPS 2000 7 Specifications are subject t...

Page 16: ...user is encouraged to try to cor rect the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect th...

Reviews: