COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION,
COMMAND_CLASS_SUPERVISION,
COMMAND_CLASS_SECURITY,
COMMAND_CLASS_SECURITY_2
Controlled Command Classes : COMMAND_CLASS_BASIC
Description : When one short press on smart button
⑧,
it will turn on the nodes of
group 8 by sending Basic_Set command and send Central_Scene_Notification to
group 1 nodes. When two short presses on smart button
⑧,
it will turn off the nodes
of group 8 by sending Basic_Set command and send Central_Scene_Notification to
group 1 nodes.
Endpoint 8 :
Device type : POWER SWITCH MULTILEVEL
Supported Command Classes : COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_SWITCH_MULTILEVEL,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION,
COMMAND_CLASS_SUPERVISION,
COMMAND_CLASS_SECURITY,
COMMAND_CLASS_SECURITY_2
Controlled Command Classes : COMMAND_CLASS_SWITCH_MULTILEVEL
Description : When the level of dimmer module 2 is changed and achieved the
desired level, it will send SWITCH_MULTILEVEL_SET command to nodes of group
9.
1. Auto report to Grouping 1 (Maximum 2 Nodes)
1-1 Reset Event Report to Lifeline
When user executes the reset function by pressing button
⑤
, it will send a
“DEVICE RESET LOCALLY NOTIFICATION” to the nodes of Group1.
For example :
Reset: [COMMAND CLASS DEVICE RESET LOCALLY, DEVICE RESET
LOCALLY NOTIFICATION]
2. Control Grouping 2~9 (Maximum 2 Nodes)
2-1
Relay On/Off Event
When the “on” or “off” state has been changed, it will send Switch Binary Set to
control the nodes of Group 2 or 7.
For example :
ON : [Command Class COMMAND CLASS MULTI CHANNEL, MULTI CHANNEL
CMD ENCAP,
Source endpoint = 0x01, (or 0x06)
Destination endpoint = 0x01,
Command Class = COMMAND_CLASS_SWITCH_BINARY,
Command = SWITCH_BINARY_SET,
Value = 0xFF]
OFF : [Command Class COMMAND CLASS MULTI CHANNEL, MULTI CHANNEL
CMD ENCAP,
11