Output Condition Settings:
When
Output Type
is set to be
Normal
,
Toggle
or
Pulse
, the options similar to the figure
below become available.
Figure 3-26
There can be a maximum of 4 conditions that can be set up to trigger an output. 2 conditions
are Door/Gate/Relay conditions and 2 conditions are Input/Reader conditions. Each
condition is related to each other through
AND/OR
.
AND
means that all conditions with
AND
must be triggered before the output is triggered.
OR
means that only 1 of the condition with
OR
is needed to be triggered before the output is triggered. It is also valid to have certain
conditions as
AND
and certain conditions as
OR
.
For
Pulse
output type, the output is triggered for the amount of time set in the
Sec
field
(seconds).
In the Output Condition settings, these
Output Type
and
Output Condition
become
available:
Output Condition
Output Type
Door #
Gate #
Relay #
Input/Reader
Access Granted Access Granted Access Granted
Access Denied
Access Denied
Access Denied
Fire Alarm
Fire Alarm
Fire Alarm
Tamper
Tamper
Tamper
Duress Event
Duress Event
Duress Event
Held Open
Held Open
Forced Open
Forced Open
Exit Button
Exit Button
Normal
Toggle
Pulse
Door Contact
Car Detection
Select
None
to
disable the
condition, or
select between
Input 1 and
Input 8,
Wiegand A and
Wiegand H, or
Reader 00 to
Reader 03 to
trigger the
output.
Available in Pulse
2 x Door/Gate/Relay Condition
2 x Input/Reader Condition