Electrical Characteristics
Absolute Maximum Ratings
Stresses exceeding the maximum ratings may permanently damage the device or affect reliability. The
device may not function or be operable outside the recommended operating conditions (see below).
Parameter
Min.
Typ.
Max.
Unit
Power Supply Voltage (VIN)
8
-
32
V
Power Supply Current
0
-
1.8
A
Analog Input Voltage
0
36
V
Relay Output Current
0
1
A
Operating Temperature
-40
-
+85
°C
Recommended Operating Conditions
Parameter
Min.
Typ.
Max.
Unit
Power Supply Voltage (VIN)
9
12/24
30
V
Power Supply Current
-
0.25/0.12
1.65
A
Internal Expansion I/O
Voltage (VIO)
0
-
3.3
V
Ambient Temperature
26
-35
25
+80
°C
Notes: