20
Pressure Maximum
To reset and redefine “9” for the pressure
bar graph, use this calibration menu.
Do
NOT adjust this setting unless you
are sure adjustments are necessary.
Adjust the pressure of the machine
so there is extremely heavy pressure
when clamping and locking the press.
Press either Arrow Key. The press now
considers this pressure as “9” on the
Pressure Bar Graph Display.
Press PRG to move to the next menu item.
Pressure Minimum
To reset and redefine “0” for the pressure
bar graph, use this calibration menu.
Do
NOT adjust this setting unless you
are sure adjustments are necessary.
Adjust the pressure of the machine so
there is barely any locking pressure
when clamping and locking the press.
Press either Arrow Key. The press now
considers this pressure as “0” on the
Pressure Bar Graph Display.
Press PRG to move to the next menu item.