27
Class
Code
Menu Item
Description
T
T1
T air i
The air temperature at the inlet of the unit
T2
T air o
The evaporator temperature at the outlet of the unit
T3
T tank t
The water temperature at the top of the unit
T4
T tank b*
The water temperature at the bottom of the unit
T5
T extra*
The temperature measured by the additional sensor
V
V1
Fan %
The actual speed of the fan in %.
V2
Input V*
The actual input signal in GC1 (0-10V) from the PV or
hygrostat in Volts.
I
I1
HP hr
The total amount of hours that the compressor has been
running
I2
EL hr
The total amount of hours that the electric heater has
been running
I3
Fan hr
The total amount of hours that the fan has been running
I4
T Avg a
The average air temperature with operating unit is dis-
played in °C since last Reset All
I5
T Avg e
The average evaporator temperature with operating unit in
°C since last Reset All
I6
HP ON
The number of START/STOPS for the entire unit life time
since last Reset All
I7
W el
The calculated instantaneous electricity consumption in W
since last Reset All
I8
MWh el
The total calculated electricity consumption in MWh since
last Reset All
I9
W th
The calculated instantaneous heating capacity is displayed
in W
I10
MWh th
The total calculated hot water production is displayed in
MWh since last Reset All
I11
EL MWh
The electricity consumption of the electric resistance in
MWh since last Reset All
R
R1
Extra*
The operation of the extra relay, for example for the
operation of a circulation pump
R2
Defrost
The operation of the relay that controls the solenoid valve
for the defrosting function is shown
R3
Fan
The fan speed is shown in %
R4
HP
The operation of the compressor is shown
R5
EL
The electric heater operation is shown