background image

Remove fan

Remove condensation level switch

Remove bypass actuator

Remove heat exchanger

DISASSEMBLY INSTRUCTIONS

L2

GN

D

24V

D

C

A

B

1

2

3

4

1

2

3

4

1

2

3

4

1

2

3

4

1

2

3

1

2

3

1

1

1

2

2

2

3

3

3

4

4

X1

X2

X3

X5

LE

D

1

LE

D

2

1

1

1

2

2

2

3

3

3

4

4

L1

L6

L8

L10

L11

L16

GN

D

GN

D

GN

D

GN

D

24V

D

C

24V

D

C

GN

D

GN

D

GN

D

GN

D

24V

D

C

A

B

Si

gna

l

Si

gna

l

0-

10V

Sen

sor

Sen

sor

T8

T9

L4

L3 A

L3 B

L3 C

L3 D

L20

L21

L17

L18

H7

H9

L17

L18

L3

L4

L1

L6

L8

L10

L11

L16

L2

L22

F1

F3

H1

H3

H

14

H

17

H7

H9

X1

MODBUS

Master

MODBUS

Display

MODBUS

CTS

RUN

ERROR

LAN OK

R

J45

ES

 2010 - O

pti

m

a 270

U

SB

-mi

ni

L

L

L

L

L

L

L

N

N

N

N

N

N

GN

D

GN

D

GN

D

GN

D

GN

D

GN

D

GN

D

GN

D

Sen

sor

3,

3V

GN

D

24V

D

C

24V

D

C

GN

D

GN

D

GN

D

GN

D

GN

D

24V

D

C

24V

D

C

A

A

B

B

GN

D

GN

D

0-

10V

0-

10V

Ta

cho

Ta

cho

Si

gna

l

Si

gna

l

Si

gna

l

0-

10V

Sen

sor

Sen

sor

Sen

sor

Sen

sor

Sen

sor

T8

T9

R1

R2

R3

R4

R5

C

R

2032

8A

2,

5A

5x

20m

m

5x

20m

m

Rh

M

X5

L22

X1

X2

X3

A

B

GN

D

+24V

D

C

A

B

GN

D

+24V

D

C

A

B

GN

D

Si

gna

l

G

ND

+24V

D

C

+24V

D

C

G

ND

Si

gna

l

1

1

2

2

3

3

4

4

24

23

22

21

21

22

23

24

JRS 23/

02/

20

21

Vers

ion 1

,2

A

B

C

D

M

ai

ns

 c

onnec

tion

1x

230V

 50H

z,

 L,

 N

, P

E

M

ax

: 10A

El

ec

tri

c P

re-

 / R

eheat

 / O

per

at

ing

1x

230V

 50H

z

M

ax

.load 1800W

Aux

. r

el

ay

 H

17

1x

230V

 50H

z

O

N

LY

 c

ont

rol

 c

ur

rent

Sens

or

 T

8 F

ros

t

Sens

or

 T

7 E

xt

rac

t ai

r

Sens

or

 T

4 E

xhaus

t ai

r

Sens

or

 T

3 O

ut

door

 ai

r

Sens

or

 T

1 S

uppl

y ai

r

Sens

or

 T

9 O

pt

ion

Ex

ter

nal

 s

top

EC

 fan E

xt

rac

t ai

r

Bl

ue

Ye

llo

w

EC

 fan S

uppl

y ai

r

Bl

ue

Ye

llo

w

EC

 fan E

xt

rac

t ai

r

1x

230V

 50H

z

Br

own

Br

own

Bl

ue

Bl

ue

Yel

low

/g

reen

H

um

idi

ty

 s

ens

or

 P

1

EC

 fan S

uppl

y ai

r

1x

230V

 50H

z

Bel

im

o C

M

230

O

N

/O

FF

 B

ypas

s

2x

230V

 50H

z

W

hi

te

C

ont

rol

 s

ignal

 for

R

ot

or

,

By

pas

s,

M

ot

or

val

ve

M

odul

at

ing R

eheat

ing

M

odul

at

ing P

reheat

ing

Pot

ent

ial

 fr

ee i

nput

 

for

 opt

ional

:

H

um

idi

st

at

Ex

trac

tor

 hood

W

hi

te

W

hi

te

M

odbus

 M

as

ter

 /

ES

1048

Br

own

Bl

ue

Yel

low

/g

reen

Yel

low

/g

reen

Yel

low

/g

reen

Br

own

Bl

ue

Br

own

Bl

ue

Fl

ow

 s

ens

or

 E

xt

rac

t ai

r

Fl

ow

 s

ens

or

 S

uppl

y ai

r

O

pt

im

a T

ouc

h D

is

pl

ay

 /

O

pt

im

a B

as

ic

 D

is

pl

ay

O

pt

im

a T

ouc

h D

is

pl

ay

 /

O

pt

im

a B

as

ic

 D

is

pl

ay

M

odbus

 M

as

ter

 /

ES

1048

M

odbus

 C

TS

Br

own

Bl

ue

G

re

en /

 B

lue

W

hit

e /

 Y

ell

ow

Br

ow

n /

 R

ed

I/O

 P

C

B

Pl

eas

e ens

ur

e s

uf

fic

ient

 

ear

thi

ng of

 the i

ns

tal

lat

ion

Ser

vi

ce m

enu  E

C

 10 =

 R

ight

LE

D

 1

  O

n =

 Int

er

net

 c

onnec

tion

LE

D

 2

  1 f

las

h     =

 E

xt

er

nal

 s

top

  2 f

las

hes

 =

 S

ens

or

 er

ror

  3 f

las

hes

 =

 H

um

idi

ty

 s

ens

or

 er

ror

  4 f

las

hes

 =

 F

an er

ror

  5 f

las

hes

 =

 S

ens

or

 F

ros

t er

ror

  6 f

las

hes

 =

 F

ire f

ai

lur

e /

 tes

t

  7 f

las

hes

 =

 F

ire f

ai

lur

e -

 D

am

per

 1

  8 f

las

hes

 =

 F

ire f

ai

lur

e -

 D

am

per

 2

  9 f

las

hes

 =

 F

ire f

ai

lur

e -

 B

ox

 1

10 f

las

hes

 =

 F

ire f

ai

lur

e -

 D

am

per

 3

11 f

las

hes

 =

 F

ire f

ai

lur

e -

 D

am

per

 4

12 f

las

hes

 =

 F

ire f

ai

lur

e -

 B

ox

 2

13 f

las

hes

 =

 R

ot

or

 al

ar

m

 

  

15

DECLARATION OF CONFORMITY

The declaration of conformity can be downloaded from www.genvex.com.

Summary of Contents for ECO 190 XL

Page 1: ...INSTALLATION MANUAL ECO 190 XL Mechanical ventilation with passive heat recovery A ...

Page 2: ...ts in heated rooms 8 Post heating of the supply air 8 Electrical Installation 9 Control and adjustment of the system 9 Optimal initial adjustment of the system 10 System maintenance 10 Trouble shooting 11 Optional equipmant for the ECO 190 XL ventilation unit 12 Spare parts 13 Electrical diagram OPT270 14 Declaration of conformity 15 Disassembly instructions 15 ...

Page 3: ...ived guidance on using the appliance in a safe way and under stand the dangers involved Children must not play with the appliance Cleaning and user maintenance must not be per formed by children without supervision Subject to change Labelling The CE label represents Genvex s assurance that the pro duct complies with all regulations imposed on the product in accordance with relevant EU directives T...

Page 4: ...nected to the right side of the ven tilation unit when the main control board of the machine is facing you Labels on the ventilation unit indicate how the ductwork is to be connected PLEASE NOTE that project specific models can be confi gured for left hand connection if this is the case the labels indicate how the ductwork should be connected On a right configured model the condensate drain and wa...

Page 5: ...2 Udsugningluft 3 Indblæsning 4 Modstrømsveks 5 Indblæsningsve 6 Udsugningsvent 7 Friskluftfilter 8 Udsugningsfilter 9 Eltilslutning 10 Kondensafløb 11 Bypass 12 Bypassklap 13 Forvarmer 14 IO Print 15 NJ45 Adapter 16 1 Fresh air 2 Discharge 3 Extract air 4 Supply air 5 Countercurrent exchanger 6 Supply air fan 7 Discharge air fan 8 Fresh air filter 9 Extract air filter 10 Electrical connection 11 ...

Page 6: ...at a sufficiently low level so that no noise is generated by the supply and extract fittings When positioning fresh air and discharge hoods grates ensure that the two air currents do not short circuit and thereby prevent the discharge air being sucked in again It is recommended that grates should be placed on the north or east side of the house to achieve optimal comfort in homes flats It is recom...

Page 7: ...tive pressure is created in the unit which means it is necessary to ensure that the water trap contains a water column of at least 50 mm Insulation of ducts in cold attics To benefit from the unit s high recovery potential efficiency the ducts must be correctly insulated Supply and extract ducts In order to minimise heat loss from the duct system in cold attics supply and extract ducts must be pro...

Page 8: ...s of the water post heating surface The sensor for controlling the motor valve is installed in the supply duct approx 500 mm after the water post heating surface so that it is not affected by radiant heat from the heater The water connection to the water post heating surface must be executed by an authorised plumber Electric post heating surface The sensor for controlling the electric heating surf...

Page 9: ...close they are to the unit 6 If a reheating surface is installed in the system the supply air temperature is set to 0 3 C below the room temperature in the home The system can now be put into operation and run until the system is adjusted using specialist ventilation measuring equip ment Electrical installation The electrical connection must be executed by an authori sed electrician See wiring dia...

Page 10: ...then rinse it e g in the bathroom using the shower head The heat exchanger plates must be handled carefully They have sharp edges and must not be damaged Fan Check the two fan wheels for dirt If they are dirty they can be cleaned with a brush bottle washer etc Supply and extract valves Clean the valves by wiping them with a dry cloth Make sure that the valve does not rotate and thus cause a change...

Page 11: ...l switch off The electric heating surface is equipped with a fire thermostat which automatically shuts off the power if the temperature exceeds 50 C When the temperature drops the heating surface automatically swit ches back on As extra security there is a built in thermal fuse which switches off if the temperature exceeds 100 C Reconnection must be performed manually This does not apply to PTC el...

Page 12: ... volume even at cold outdoor temperatures Condensate pump the ECO 190 XL can be supplied with a factory fitted condensate pump that makes it possible to divert condensate even in difficult conditions Note only recommended in combination with condensation level switch Condensation level switch must be connected to external start stop on the main circuit board for automatic shut off of the ventilati...

Page 13: ...69875 Optima 270 print 2 069820 XL Fan incl cabinet 3 069344 Exchanger GS18 x 460 alu 069345 Exchanger GS18 x 460 plastic 4 069370 Filter G4 Coarse 069371 Filter M5 ePM10 069372 Filter F7 ePM1 No Item no Description 5 069221 Packing list 6 069382 Base plate assembled 7 060536 Belimo motor CM230 FR 8 069761 Bypass flap large 9 069354 Cable entry 2 10 069365 Level switch complete ...

Page 14: ...Exhaust air Sensor T3 Outdoor air Sensor T1 Supply air Sensor T9 Option External stop EC fan Extract air Blue Yellow EC fan Supply air Blue Yellow EC fan Extract air 1x230V 50Hz Brown Brown Blue Blue Yellow green Humidity sensor P1 EC fan Supply air 1x230V 50Hz Belimo CM230 ON OFF Bypass 2x230V 50Hz White Control signal for Rotor Bypass Motorvalve Modulating Reheating Modulating Preheating Potenti...

Page 15: ...ve fan Remove condensation level switch Remove bypass actuator Remove heat exchanger DISASSEMBLY INSTRUCTIONS 15 DECLARATION OF CONFORMITY The declaration of conformity can be downloaded from www genvex com ...

Page 16: ...n society as a whole in fact you can recover up to 95 of the heat energy with a Genvex system All Genvex systems are rated with energy label A The original Genvex units are assembled by skilled and expe rienced technicians and have a lifetime that in many cases is measured in decades The units are approved by all applicable stan dards and are easy to operate and service Last but not least all Genv...

Reviews: