General Precautions (cont’d)

Fuel and Oil (cont’d)

 • Do not smoke, or allow sparks, flames or other sources of ignition around the engine and fuel   
    tank. Fuel vapors are explosive.

 • Keep grounded conductive objects, such as tools, away from exposed, live electrical parts and  
   connections to avoid sparking or arcing. These events could ignite fumes or vapors.

 • Do not refill the fuel tank while the engine is running or while the engine is still hot. Do not   
    operate the generator with known leaks in the fuel system 

 • Excessive buildup of unburned fuel gases in the exhaust system can create a potentially    
   explosive condition. This buildup can occur after repeated failed start attempts, valve testing, or  
   hot engine shutdown. If this occurs, open exhaust system drain plugs, if equipped, and allow the  
   gases to dissipate before attempting to restart the generator. 

 • Use only engine manufacturer recommended fuel and oil.

Hot Components

 

WARNING! ENGINE AND EXHAUST SYSTEM PARTS BECOME VERY 

 

HOT AND REMAIN HOT FOR SOME TIME AFTER THE ENGINE IS RUN. WEAR  

 

INSULATED GLOVES OR WAIT UNTIL THE ENGINE AND EXHAUST SYSTEM  

 

HAVE COOLED BEFORE HANDLING THESE PARTS.

Power Output 

This generator is not designed to power sensitive electronic equipment (including computers           
and medical devices) without the addition of an approved line conditioner, which is sold separately.

 

CAUTION: ATTEMPTING TO POWER SENSITIVE ELECTRONIC EQUIPMENT  

 

WITHOUT THE USE OF AN APPROVED LINE CONDITIONER MAY CAUSE   

 

DAMAGE TO THE EQUIPMENT. GENTRON IS NOT RESPONSIBLE  

 

FOR ANY DIRECT OR INDIRECT DAMAGE CAUSED BY FAILURE TO USE AN  

 

APPROVED LINE CONDITIONER.

Summary of Contents for APG3301C

Page 1: ...wner s Manual 4 3 12 1 0 1 04 2 0 230 2 12 0 1 2 0 Please read and save these instructions Voltage Meter AC Outlet Engine Switch ON OFF Circuit Protector AC DC ON OFF For Charging Battery Only DC 12V...

Page 2: ...her partly enclosed areas Deadly levels of carbon monoxide can build up in these areas Using a fan or opening windows and doors does NOT supply enough fresh air ONLY use a generator outdoors and far a...

Page 3: ...lation 23 Specifications 25 WARNING READ AND UNDERSTAND ALL SAFETY PRECAUTIONS IN THIS MANUAL BEFORE OPERATING FAILURE TO COMPLY WITH INSTRUCTIONS IN THIS MANUAL COULD RESULT IN PERSONAL INJURY PROPER...

Page 4: ...ness hours at the service center location and the availibility of replacement parts All decisions of Gentron with regard to this limited warranty shall be final This warranty gives you specific legal...

Page 5: ...uired oil adjustments or other installation and start up costs Expendable parts or accessories supplied with the product which are expected to become inoperative or unusable after a reasonable period...

Page 6: ...ions Be sure to retain them for future use WARNING WARNINGS INDICATE A CERTAINTY OR STRONG POSSIBILITY OF PERSONAL INJURY OR DEATH IF INSTRUCTIONS ARE NOT FOLLOWED CAUTION CAUTIONS INDICATE A POSSIBIL...

Page 7: ...General Precautions WARNING FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN SEVERE INJURY OR DEATH DANGER Carbon Monoxide Carbon Monoxide Generator exhaust contains high levels of carbon monoxide...

Page 8: ...hot engine shutdown If this occurs open exhaust system drain plugs if equipped and allow the gases to dissipate before attempting to restart the generator Use only engine manufacturer recommended fue...

Page 9: ...ized plug where one blade is wider than the other This plug fits in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qua...

Page 10: ...e electrical characteristics and rated capacities of the generator Before servicing equipment powered by the generator disconnect the equipment from its power input Keep all electrical equipment clean...

Page 11: ...it on or off Any generator that cannot be controlled with the power switch is dangerous and must be replaced Generator Use and Care Make sure the power switch is in its OFF position and disconnect th...

Page 12: ...enance instructions may create a risk of electric shock or injury Heart Pacemakers WARNING PEOPLE WITH PACEMAKERS SHOULD CONSULT THEIR PHYSICIAN S BEFORE USING THIS PRODUCT ELECTROMAGNETIC FIELDS IN C...

Page 13: ...of the generator frame at its low side For trailer installation the generator should be mounted on the center point of the trailer over the wheels The trailer must be capable of supporting the weight...

Page 14: ...safety eye goggles and safety hat Do not alter or adjust any part of the generator that is assembled and supplied by the manufacturer Always follow and complete scheduled engine and generator maintena...

Page 15: ...use only UL approved cords having the correct gauge and length according to the following table Nameplate Amps Cord Lengths full load 0 5 16 16 12 12 5 1 8 16 14 10 8 1 12 14 12 12 1 15 12 10 15 20 1...

Page 16: ...15 Assembly Handle Assembly Insert washers on bolts Place bolts through handle and screw in to generator See illustration below Owner s Manual Washers Bolts Generator Handle...

Page 17: ...TED AT THE BOTTOM OF THE ENGINE CRANKCASE FILL THE ENGINE S CRANKCASE UNTIL THE OIL LEVEL IS LEVEL WITH THE UPPER MARKED LINE ON THE DIPSTICK THEN SCREW THE DIPSTICK BACK INTO THE OIL FILL HOLE Pull S...

Page 18: ...re you start generator make sure the unit has enough oil and fuel Also disconnect all loads from generator Voltage Meter Engine Switch ON OFF Put the Choke lever on the Choke position Put the Choke le...

Page 19: ...r s Manual Operation cont d 1BONNCHA IQH H L NIL Turn the engine switch to the Off position NOTE Disconnect all loads from generator Voltage Meter Engine Switch ON OFF Turn the fuel valve to the Off p...

Page 20: ...D LINE CONDITIONER MAY CAUSE DAMAGE TO THE EQUIPMENT ALL POWER IS NOT RESPONSIBLE FOR ANY DIRECT OR INDIRECT DAMAGE CAUSED BY FAILURE TO USE AN APPROVED LINE CONDITIONER 2 Once the generator is runnin...

Page 21: ...NNECT THE NEGATIVE LEAD OF THE POWER CORD TO THE NEGATIVE TERMINAL ON THE GENERATOR 3 Start and run the engine as described above 4 When finished using the generator turn the engine power switch to it...

Page 22: ...lean the spark plug with a wire brush if it is to be reused 4 Measure the plug gap with a feeler gauge 5 Check that the spark plug washer is in good condition 6 After the spark plug is seated tighten...

Page 23: ...ion If an engine problem occurs have it checked by a qualified service technician before further use Do not use damaged equipment Before each use make sure the engine s oil and fuel levels are adequat...

Page 24: ...APPROXIMATELY 53 POUNDS USE CARE AND THE PROPER LIFTING OR HOISTING EQUIPMENT WHEN MOVING IT TO THE INSTALLATION LOCATION ALWAYS CONNECT HOIST LINES TO THE FRAME OF THE GENERATOR General Location Make...

Page 25: ...g 3 8 diameter expansion anchor bolts not supplied Grounding NOTE IT IS RECOMMENDED THAT ONLY A TRAINED AND LICENSED ELECTRICIAN PERFORM THIS PROCEDURE Owner s Manual Brass Rod electrode Ground Connec...

Page 26: ...attage 900w Peak Wattage 1200w Outlet One 120V outlet 25 Specifications AC electrical DC electrical 12V 8 3 A Gasoline engine Fuel Type Gasoline Capacity 1 3 gallons 5 liters Running time 9 hrs 1 2 lo...

Page 27: ...APG3301C A 02 WD EG HT152 A02 Oil seal 2 APG3301C A 03 WD EG HT152 A03 Bearing 6203 1 APG3301C A 04 WD EG HT152 A04 Crankcase gasket 1 APG3301C A 05 WD EG HT152 A05 Drain bolt 2 APG3301C A 06 WD EG HT...

Page 28: ...Y 152 B04 Head cover comp 1 APG3301C B 05 WD EG LY 152 B05 Head cover gasket 1 APG3301C B 06 WD EG LY 152 B06 Press board 1 APG3301C B 07 WD EG LY 152 B07 Bolt M6x90 2 APG3301C B 08 WD EG LY 152 B08 F...

Page 29: ...4 WD EG LY152 C04 Connecting rod cover 1 APG3301C C 05 WD EG LY152 C05 Flange bolt 2 APG3301C C 06 WD EG LY152 C06 First piston ring 1 APG3301C C 07 WD EG LY152 C07 Second piston ring 1 APG3301C C 08...

Page 30: ...PG3301C D 04 WD EG LY152 D04 Slide block 1 APG3301C D 05 WD EG LY152 D05 Lock ring 1 APG3301C D 06 WD EG LY152 D06 Valve lifter 2 APG3301C D 07 WD EG LY152 D07 Push rod 2 APG3301C D 08 WD EG LY152 D08...

Page 31: ...Spring retainers 2 APG3301C D 15 WD EG LY152 D15 Rocker ring 4 APG3301C D 16 WD EG LY152 D16 Rocker seat 1 APG3301C D 17 WD EG LY152 D17 Rocker arm shaft 2 APG3301C D 18 WD EG LY152 D18 Adjusters scre...

Page 32: ...Filter cover 1 APG3301C E 03 WD EG LY152 E03 Air cleaner element 1 APG3301C E 04 WD EG LY152 E04 Hold rack 1 APG3301C E 05 WD EG LY152 E05 Net M6 2 APG3301C E 06 WD EG LY152 E06 Filter seat 1 APG3301C...

Page 33: ...1 APG3301C F 04 WD EG LY152 F04 Main nozzle 1 APG3301C F 05 WD EG LY152 F05 Gasket 1 APG3301C F 06 WD EG LY152 F06 Float chamber body 1 APG3301C F 07 WD EG LY152 F07 Gasket 1 APG3301C F 08 WD EG LY15...

Page 34: ...Part No Part No Description Qty APG3301C F 13 WD EG LY152 F13 Main jet 1 APG3301C F 14 WD EG LY152 F14 Pilot jet 1 APG3301C F 15 WD EG LY152 F15 Bolt 1 APG3301C F 16 WD EG LY152 F16 Spring 1 APG3301C...

Page 35: ...WD EG LY152 G03 Platen 1 APG3301C G 04 WD EG LY152 G04 Spring washer 1 APG3301C G 05 WD EG LY152 G05 Handle 1 APG3301C G 06 WD EG LY152 G06 Washer 1 APG3301C G 07 WD EG LY152 G07 Shaft 1 APG3301C G 08...

Page 36: ...7 WD EG LY152 G17 Lock ring 1 APG3301C G 18 WD EG LY152 G18 Washer 1 APG3301C G 19 WD EG LY152 G19 Governor shaft 1 APG3301C G 20 WD EG LY152 G20 Lock ring 1 APG3301C G 21 WD EG LY152 G21 Gear 1 APG33...

Page 37: ...ing frame 1 APG3301C H 02 WD EG LY152 H02 Stopping protective wires 1 APG3301C H 03 WD EG LY152 H03 Ignition coil assy 1 APG3301C H 04 WD EG LY152 H04 Flange bolt 2 APG3301C H 05 WD EG LY152 H05 Spark...

Page 38: ...Y152 I04 Starter spring 1 APG3301C I 05 WD EG LY152 I05 Recoil starter rope 1 APG3301C I 06 WD EG LY152 I06 Drum sheave 1 APG3301C I 07 WD EG LY152 I07 Drive pawls 2 APG3301C I 08 WD EG LY152 I08 Clip...

Page 39: ...G LY152 I14 Starter pulley 1 APG3301C I 15 WD EG LY152 I15 Behind cover 1 APG3301C I 16 WD EG LY152 I16 Bolt 2 APG3301C I 17 WD EG LY152 I17 Front cover 1 APG3301C I 18 WD EG LY152 I18 Air shroud 1 AP...

Page 40: ...1C J 04 WD GG WDF1200E J04 Rotor 1 APG3301C J 05 WD GG WDF1200E J05 Stator 1 APG3301C J 06 WD GG WDF1200E J06 Magneto wire protect cover 1 APG3301C J 07 WD GG WDF1200E J07 Bolt M6X12 2 APG3301C J 08 W...

Page 41: ...gasket 1 APG3301C J 15 WD GG WDF1200E J15 Bolt M8X180 1 APG3301C J 16 WD GG WDF1200E J16 Magneto cover 1 APG3301C J 17 WD GG WDF1200E J17 Gasket 2 APG3301C J 18 WD GG WDF1200E J18 Spring gasket 2 APG3...

Page 42: ...C K 05 WD GG WDF1200E K05 Hexagon flange bolt M6X16 4 APG3301C K 06 WD GG WDF1200E K06 Gasket 4 APG3301C K 07 WD GG WDF1200E K07 Spring gasket 4 APG3301C K 08 WD GG WDF1200E K08 Bolt M6 4 APG3301C K 0...

Page 43: ...cuit breaker 1 APG3301C L 04 WD GG WDF1200E L04 DC circuit breaker 1 APG3301C L 05 WD GG WDF1200E L05 Engine switch 1 APG3301C L 06 WD GG WDF1200E L06 AC socket 1 APG3301C L 07 WD GG WDF1200E L07 Left...

Page 44: ...rt No Description Qty APG3301C M 01 WD GG WDF1200E M01 Gasket 1 APG3301C M 02 WD GG WDF1200E M02 Muffler 1 APG3301C M 03 WD GG WDF1200E M03 Back plank 1 APG3301C M 04 WD GG WDF1200E M04 Back shell 1 A...