PROCESS DESCRIPTION
Gentherm Global Power Technologies
Page 24
It must be noted that if an area is defined as hazardous (i.e. may contain hazardous gases
such as in a Class 1, Division 2 area) then TEG models 1120 & 1500 are the only GPT TEGs
suitable for installation in these hazardous areas. The addition of a flame arrestors does not
make the Models P-5050 N, P-5100 N, P-5100 H and P-5100 L TEGs suitable for use in a
hazardous area. For hazardous area use, TEGs require reduced surface temperatures (below
hazardous gas ignition temperatures), addition of air intake and exhaust flame arrestors, and
other modifications.
It is the customers responsibility concerning the installed location and operation of a TEG
(with or without a flame arrestor), and installations should comply with all applicable
regulations.
4.8
OPTIONAL VSR TERMINAL BLOCK
An optional wiring harness with terminal block can be provided for easy access to the voltage
sensing relay and current sense connections. This terminal connects to the regulating limiter
VSR1, VSR2, and current sense outputs to a terminal block on the inside of the TEG cabinet.
This option provides #6 screw terminals and will take up to wire size #10 AWG with an
appropriate ring or fork terminal.