background image

Visual Inspection

 

 

Check the face seal material for damage 

 

Check the face seal attachment to the chassis and visor of the PureLite XStream

 

Check the visor seal for damage

 
Replace any damaged parts including scratched or damaged visors.

Airflow Pre-Use Check

 

Ensure that the air filters have been 
installed correctly as shown in Fig. 3

Check the airflow as shown in Fig. 4

 

Turn the helmet upside down 
and locate the airflow indicator 
on the four slots at the front of 
the helmet.

 

Press the red on/off switch to 
operate the fan. An audible tone 
should sound briefly one time. 
The red ball is raised to the 
top of the indicator tube if the 
system is operating correctly.

 

If the red ball is raised to less 
than half the height of the tube 
then either the battery charge is 
low or the filters are blocked and 
need replacing.

Low Battery Warning

 

If an audible regular intermittent tone sounds recharge or replace the battery pack.

Fig. 3

Fig. 4

On/Off Switch

Air Filter

Red Ball

5

Summary of Contents for PUREFLO PURELITE XSTREAM

Page 1: ...PureLite XStream Self Contained Powered Air Purifying Visor System User Manual This product is covered by one or more patents For more information visit www gentexcorp com patents 414607...

Page 2: ......

Page 3: ...proval for Use Suitability for Use Preparation for Use Wearing and Using Parts List Servicing Storage Technical Specification Decontamination Return Procedure Customer Support 1 2 2 4 6 8 10 17 17 18...

Page 4: ......

Page 5: ...rotection The PureLite XStream is powered by a rechargeable battery pack held inside the unit Air is filtered through the unit s filters to provide a constant flow of clean air over the face A face se...

Page 6: ...BY NIOSH for use against solid particulates only Eye Protection ANSI ISEA Z87 1 2015 personal eye and face protection Meets high Impact requirements Z87 Head Protection Not ANSI approved The PureLite...

Page 7: ...rom high speed particles thus creating a hazard to the wearer Never modify or alter this product except as directed in the service tasks contained in these instructions Materials which may come into c...

Page 8: ...shown in Fig 1 Slide the battery pack into its housing as shown in Fig 2 Fit the battery charger connector into the rear of the electronics unit and connect the charger to a mains AC supply the LED li...

Page 9: ...et upside down and locate the airflow indicator on the four slots at the front of the helmet Press the red on off switch to operate the fan An audible tone should sound briefly one time The red ball i...

Page 10: ...and diameter by pulling the knob out and rotating for head size push the knob in to secure as shown in Fig 5B Ensure face seal is above the ears and check that the face seal is taut so that there are...

Page 11: ...id Do not use organic solvents or abrasive cleaning agents on any part of the equipment Launder the face seal and linings as required using a mild solution of a household detergent and water Disposal...

Page 12: ...ment Filters 1 Pair 5 PL01171 4SP Battery Pack 1 6 PL01172 5SP Battery Charger 1 7 PL01178 4SP Airflow Indicator 1 8 PL01179 4SP PC Board Switch Assembly 1 9 PL01174 3SP Main Cover 1 10 PL01177 4SP Fa...

Page 13: ...Fig 7 Item Order Description Qty 17 PL01182SP 4SP Charge Cradle 1 Accessories Reference Fig 7 9...

Page 14: ...placement Replace the old or damaged visor assembly as shown in Fig 8 below Release nuts and push screws inwards release the front tab and lift visor from the helmet Fit replacement visor ensuring slo...

Page 15: ...see Headband assembly and Fig 10 on page 12 and remove the crown pad by separating the hook loop fastener Separate the crown strap at the adjustment and remove the elastic loops on each side Pull face...

Page 16: ...on page 11 and install the new headband assembly as shown in Fig 10 below Release nuts and screw and remove the headband from the helmet Assemble anti rotating cap and screw retainer to headband noti...

Page 17: ...ig 3 Hold the neck of the fitted air filter and push firmly towards sealing face to release from securing tabs and lift filter upwards to remove Discard appropriately Locate new air filter against sea...

Page 18: ...r duct Separate fan motor from front air duct Fold back both seals on replacement fan motor assembly with electrical lead point downwards locate with front air duct and secure by unfolding seal over d...

Page 19: ...Fig 11 Fig 1 15...

Page 20: ...SERVICING CONTINUED Electronics Unit Replacement Lift the cover as shown in Fig 1 and replace the electronics unit as shown in Fig 12 below Fig 1 Fig 12 16...

Page 21: ...mperature Range Charging 41 F to 104 F Use 23 F to 104 F Storage 41 F to 104 F Airflow Internal 2 2 lbs nominal Minimum 5 4 to 6 1 cfm Power Supply Battery Pack 3 cell nominal 3 6V capacity 3 5 Ah per...

Page 22: ...vide MSDS sheets for all hazardous materials supply this information separately and externally attached to the packaging Failure to perform these tasks will result in return of the unit without action...

Page 23: ...CUSTOMER SUPPORT Gentex Corporation 324 Main Street Simson PA USA 18407 Tel 570 282 3550 or 800 251 7377 email sales helmetsystems com www gentexcorp com 19...

Page 24: ...PureLite XStream User Manual REV 20181016 Copyright 2018 Gentex Corporation PureFlo is a trademark of Gentex Corporation or its affiliates...