background image

The equipment should be stored in dry, clean conditions away from direct sunlight, 
sources of heat, petrol and solvent vapors.
Store the equipment within the temperature range 41°F to 104°F and the humidity 
range 0-90%.

Weight   

 

2.2 lbs nominal

Head Size Range   

54- 61cm

Humidity   

 

0-90% storage and use (store out of direct sunlight)

Temperature Range
 

Charging   

41°F  to 104°F

 

Use 

 

23°F  to 104°F

 

Storage   

41°F  to 104°F

Airflow

Internal   

 

2.2 lbs nominal

Minimum  

 

5.4 to 6.1 cfm

Power Supply

Battery Pack 

 

3 cell, nominal 3.6V, capacity 3.5 Ah per pack NiMH

Battery Life 

 

8 hrs (fully charged battery pack fitted)

Charging Method/Rate 

Mains charger, 14 hrs from fully discharged

Battery Charger

Input 

   120V

Nominal Power Consumption   

4W

No Load Output 

 

 

12VDC

Nominal Output Voltage @ 4.2 v 

300mA

 

 

 

 

IP 20 Indoor Use Only

    CE 

EN 

60335-1, 

60335-2-29

STORAGE

TECHNICAL SPECIFICATION

17

Summary of Contents for PUREFLO PURELITE XSTREAM

Page 1: ...PureLite XStream Self Contained Powered Air Purifying Visor System User Manual This product is covered by one or more patents For more information visit www gentexcorp com patents 414607...

Page 2: ......

Page 3: ...proval for Use Suitability for Use Preparation for Use Wearing and Using Parts List Servicing Storage Technical Specification Decontamination Return Procedure Customer Support 1 2 2 4 6 8 10 17 17 18...

Page 4: ......

Page 5: ...rotection The PureLite XStream is powered by a rechargeable battery pack held inside the unit Air is filtered through the unit s filters to provide a constant flow of clean air over the face A face se...

Page 6: ...BY NIOSH for use against solid particulates only Eye Protection ANSI ISEA Z87 1 2015 personal eye and face protection Meets high Impact requirements Z87 Head Protection Not ANSI approved The PureLite...

Page 7: ...rom high speed particles thus creating a hazard to the wearer Never modify or alter this product except as directed in the service tasks contained in these instructions Materials which may come into c...

Page 8: ...shown in Fig 1 Slide the battery pack into its housing as shown in Fig 2 Fit the battery charger connector into the rear of the electronics unit and connect the charger to a mains AC supply the LED li...

Page 9: ...et upside down and locate the airflow indicator on the four slots at the front of the helmet Press the red on off switch to operate the fan An audible tone should sound briefly one time The red ball i...

Page 10: ...and diameter by pulling the knob out and rotating for head size push the knob in to secure as shown in Fig 5B Ensure face seal is above the ears and check that the face seal is taut so that there are...

Page 11: ...id Do not use organic solvents or abrasive cleaning agents on any part of the equipment Launder the face seal and linings as required using a mild solution of a household detergent and water Disposal...

Page 12: ...ment Filters 1 Pair 5 PL01171 4SP Battery Pack 1 6 PL01172 5SP Battery Charger 1 7 PL01178 4SP Airflow Indicator 1 8 PL01179 4SP PC Board Switch Assembly 1 9 PL01174 3SP Main Cover 1 10 PL01177 4SP Fa...

Page 13: ...Fig 7 Item Order Description Qty 17 PL01182SP 4SP Charge Cradle 1 Accessories Reference Fig 7 9...

Page 14: ...placement Replace the old or damaged visor assembly as shown in Fig 8 below Release nuts and push screws inwards release the front tab and lift visor from the helmet Fit replacement visor ensuring slo...

Page 15: ...see Headband assembly and Fig 10 on page 12 and remove the crown pad by separating the hook loop fastener Separate the crown strap at the adjustment and remove the elastic loops on each side Pull face...

Page 16: ...on page 11 and install the new headband assembly as shown in Fig 10 below Release nuts and screw and remove the headband from the helmet Assemble anti rotating cap and screw retainer to headband noti...

Page 17: ...ig 3 Hold the neck of the fitted air filter and push firmly towards sealing face to release from securing tabs and lift filter upwards to remove Discard appropriately Locate new air filter against sea...

Page 18: ...r duct Separate fan motor from front air duct Fold back both seals on replacement fan motor assembly with electrical lead point downwards locate with front air duct and secure by unfolding seal over d...

Page 19: ...Fig 11 Fig 1 15...

Page 20: ...SERVICING CONTINUED Electronics Unit Replacement Lift the cover as shown in Fig 1 and replace the electronics unit as shown in Fig 12 below Fig 1 Fig 12 16...

Page 21: ...mperature Range Charging 41 F to 104 F Use 23 F to 104 F Storage 41 F to 104 F Airflow Internal 2 2 lbs nominal Minimum 5 4 to 6 1 cfm Power Supply Battery Pack 3 cell nominal 3 6V capacity 3 5 Ah per...

Page 22: ...vide MSDS sheets for all hazardous materials supply this information separately and externally attached to the packaging Failure to perform these tasks will result in return of the unit without action...

Page 23: ...CUSTOMER SUPPORT Gentex Corporation 324 Main Street Simson PA USA 18407 Tel 570 282 3550 or 800 251 7377 email sales helmetsystems com www gentexcorp com 19...

Page 24: ...PureLite XStream User Manual REV 20181016 Copyright 2018 Gentex Corporation PureFlo is a trademark of Gentex Corporation or its affiliates...

Reviews: