16
•
To adjust the timing you will need to use
the allen key provided (1.2mm)
•
Turning the screw in clockwise will
reduce the run time.
•
Turning the screw anti clockwise will
increase the run time
Fixed Timing Adjustment
Please contact GENTEC before changing
flow cups
Our Flostop range is available in the following
fixed timing options
These options are available upon request
and are factory installed. *Refer to the chart
below
Changing the flow cup yourself may void the
product warranty.
ADJUSTABLE CARTRIDGE (0 TO 40 SECONDS)
This option is suitable for the following references: TFT1010ADJ,
TFT3600, TFT1015KIT, TFT1016KIT
Time Adjustment
*Use 350Kpa pressure reduction valve for extended life and better operation
FCC.
Description
TFT9050
Flow cup 4 - 6 Sec
TFT9052
Flow cup 8 - 12 Sec
TFT9053
Flow cup 12 - 16 Sec
TFT9054
Flow cup 40 Sec