background image

4

Product Range

TFT3600 / TFT3600 KIT

FLOOR / WALL MOUNTED FOOT OPERATED VALVE

* KIT WITH SPOUT AVAILABLE

TFT1010

TFT1010ADJ

SINGLE TEMPERATURE STRAIGHT VALVE

SINGLE TEMPERATURE STRAIGHT VALVE WITH 

ADJUSTABLE CARTRIDGE

Summary of Contents for TFT1010

Page 1: ...ve TFT3500 Foot Operated Valve TFT3600 TFT3700 Straight Shower Valve TFT1010 Adjustable Shower Valve TFT1010ADJ Shower Control Valve TFT1015KIT Shower Mixer Control Valve TFT1016KIT INSTALLATION MANUA...

Page 2: ...chnical Drawings 6 Unit Components 8 Wall Mounted Showers Installation 10 Outlet Installation 12 Knee Valve Installation 13 Pedal Valve Installation 14 Single Temp Straight Valve 15 Time Adjustment In...

Page 3: ...me complies with food preparation regulations Installation and servicing For durability please ensure to install all parts including strainers flow regulators Usage features Hands Free products availa...

Page 4: ...uct Range TFT3600 TFT3600 KIT FLOOR WALL MOUNTED FOOT OPERATED VALVE KIT WITH SPOUT AVAILABLE TFT1010 TFT1010ADJ SINGLE TEMPERATURE STRAIGHT VALVE SINGLE TEMPERATURE STRAIGHT VALVE WITH ADJUSTABLE CAR...

Page 5: ...alia com au TFT3500 TFT3500KIT KNEE OPERATED VALVE KIT WITH SPOUT AVAILABLE TTFT1016KIT TFT1015 KIT SHOWER MIXER VALVE WITH IN WALL STAINLESS STEEL BOX SINGLE TEMPERATURE SHOWER VALVE WITH IN WALL STA...

Page 6: ...J SINGLE TEMPERATURE STRAIGHT SHOWER VALVE SINGLE TEMPERATURE STRAIGHT SHOWER VALVE WITH ADJUSTABLE CARTRIDGE GENTECH AUSTRALIA PTY LTD 68 61 45 5 6 5 G1 2 30 5 37 5 64 5 325 G1 2 33 37 5 G1 2 95 37 5...

Page 7: ...ERATURE SHOWER VALVE WITH IN WALL STAINLESS STEEL BOX SHOWER MIXER VALVE WITH IN WALL STAINLESS STEEL BOX GENTECH AUSTRALIA PTY LTD 54 42 30 36 35 50 5 G 1 2 17 15 41 53 5 236 182 5 G 1 2 GENTECH AUST...

Page 8: ...8 KNEE OPERATED VALVE TFT1015KIT Unit components Pressure exceding 450 kPa will void warranty...

Page 9: ...nt Note For the Maintenance Instructions see Pag 17 OPERATION REQUIREMENTS Pressure Temperature Value Min Continuous Flow Working Pressure 150kPa Max Continuous Flow Working Pressure 450kPa Optimum Fl...

Page 10: ...x into the wall firmly 2 Screw the main valve into the box and locate the outlet in the vertical position Product performs best at 350kPa Note Ensure the button on the valve body is aligned with the w...

Page 11: ...FT1016KIT only screw in levers for hot and cold controls and use Lockseal to secure Connect hot left and cold right water on each side of the mixer Compliance The mixer handle is a blender valve only...

Page 12: ...led to the requirements of AS NZS 3500 by a qualified plumber Your mixer comes to you already factory assembled and tested We do not recommend the dismantling of any internal part of the mixer The mix...

Page 13: ...ace using the necessary screws to mount firmly onto the wall Ensure the arrow on the knee valve body figure 2 is facing up when connected to the water inlet and outlet 6 Place the filter in the water...

Page 14: ...r or wall to prevent any movement while operating the valve 4 Use the 4 mounting screws to screw the pedal valve into place How to adjust timing For time delay adjustment see page 17 Important note We...

Page 15: ...is facing the dicrection of the outlet 6 Connect the water inlet and outlet 7 Push into the button the colour indicator for hot or cold water Note The difference between the TFT1010 and the TFT 1010A...

Page 16: ...xed timing options These options are available upon request and are factory installed Refer to the chart below Changing the flow cup yourself may void the product warranty ADJUSTABLE CARTRIDGE 0 TO 40...

Page 17: ...nd remove the cartridge 2 Undo the stopper 3 Set aside the crown ring 4 Set aside the head valve from the stem 5 Remove the washer Gaco from the head valve and replace with the new washer gaco 6 Remov...

Page 18: ...a reasonable time 2 2 8 completed credit card authorisation in the form set out in Schedule 2 to these conditions accepting liability in accordance with clause 2 6 if the product is not faulty 2 3 The...

Page 19: ...tent permitted by law the Principal 4 2 1 excludes all implied warranties and conditions under statute or general law as to merchantability description quality suitability fitness for purpose or other...

Page 20: ...by the machine from which that fax is sent and which confirms transmission of that fax in its entirety unless that local time is not a Business Day or is after 5pm on a Business Day in which case tha...