page 23
Genquip Gi1000 Digital Inverter Petrol Generator
Troubleshooting
TROUBLE
POSSIBLE CAUSE
SUGGESTED REMEDY
Generator stops
(continued)
Generator may not be
correctly ventilated with free
flowing air.
Check and make sure that
the generator is located in
a appropriately ventilated
environment. If not relocate
the generator to a well-
ventilated location.
Generator fuel cap breather
set on the closed position.
Check that the generator
fuel cap has the breather
located switch located on
the "on" position, allowing
air to mix with the fuel. If
the breather cap is located
in the "off' position rotate
switch on the cap to the
"on" position.
Generator air filter may
need cleaning.
Remove the air filter. Check
to make sure that the air
filter is clean. If required
clean, dry and re-install the
air filter.
Generator fuel filter may be
blocked.
The internal in-line filter
may be blocked. Contact
your service agent for a
service/replacement of the
fuel filter.
Generator running
rough
Has the choke been
elevated to the Run position.
Check to make sure that the
choke has been elevated
to the run position. If not
elevate the choke to the run
position.
Has the generator got old
fuel in it, that has been
sitting still for a while.
If so empty out the old fuel
and replace it with new
fresh fuel.
Appliance is not
working or stops
working
Unplug the appliance from
the generator and check for
defect.
If appliance has a defect
follow the instructions as
per the operation/owners
manual.
Summary of Contents for Gi1000
Page 2: ...page 2 Genquip Gi1000 Digital Inverter Petrol Generator Notes ...
Page 24: ...page 25 Genquip Gi1000 Digital Inverter Petrol Generator Notes ...
Page 25: ...page 26 Genquip Gi1000 Digital Inverter Petrol Generator Notes ...
Page 26: ...page 27 Genquip Gi1000 Digital Inverter Petrol Generator Notes ...