13
ENGLISH
BASIC PROGRAMMING
F
Display
Function
Default
FUNCTION LOGICS (see tab. 3/a - g):
= Automatic
= "Stepped" automatic
= "Safety" Automatic
= Semi-automatic
= "Stepped" Semi-automatic
= Dead-man
= "B" Semi-automatic
PAUSE TIME:
This has effect only if the automatic logic was
selected. Adjustable from
to
sec. in
one-second steps.
Subsequently, display changes to minutes
and tens of seconds (separated by a point)
and time is adjusted in 10-second steps, up
to the maximum value of
minutes.
E.g. if the display shows
, pause time is
2 min. and 50 sec.
FORCE:
Adjusts Motor thrust.
= minimum force
= maximum force
OPENING DIRECTION:
Indicates the gate opening movement and
makes it possible not to change the motor
and limit-switch connections on the terminal
board.
= Right-hand opening movement
= Left-hand opening movement
5. PROGRAMMING
To program operation of the automated system, you have to
access the "
PROGRAMMING
" mode.
Programming is split into two parts:
BASIC
and
ADVANCED
.
5.1. BASIC PROGRAMMING
To access BASIC PROGRAMMING, press key
F
:
•if you press it (and hold it down), the display shows the name of
the first function.
•if you release the key, the display shows the value of the function
that can be modified with keys
+
and
-
.
•if you press
F
again (and hold it down), the display shows the
name of the next function, etc.
•when you reach the last function, press
F
to exit the program,
and the display resumes showing the gate status.
The following table shows the sequence of functions accessible in
BASIC PROGRAMMING:
ADVANCED PROGRAMMING
F
+
+
Display
Function
Default
MAXIMUM TORQUE AT INITIAL THRUST:
The motor operate at maximum torque
(ignoring the torque setting) at start of
movement. Useful for heavy leaves.
= Active
= Disabled
FINAL BRAKING:
When the gate engages the opening or
closing limit-switch, a braking stroke can
be selected to ensure the leaf is stopped
immediately. If decelerations are selected,
braking starts when they finish.
At
value, braking is disabled.
Time can be adjusted from
to
sec. in 0.1-second steps.
E.g. if the display indicates
, braking
time is 1 second.
= Braking disabled
from
to
= Timed braking
FAIL SAFE:
If this function is activated, it enables a
function test of the photocells before any
gate movement. If the test fails (photocells
not serviceable signalled by value
on
the display), the gate does not start moving.
= Active
= Disabled
PRE-FLASHING (5 s):
Activates the flashing lamp for 5 sec. before
start of movement.
= Active
= Disabled
5.2. ADVANCED PROGRAMMING
To access ADVANCED PROGRAMMING, press key
F
and, as you
hold it down, press key
+
:
•if you release key
+
, the display indicates the name of the first
function.
•if you release key
F
too, the display shows the value of the
function that can be modified with keys
+
and
-
.
•if you press key
F
(and hold it down), the display shows the name
of the next function, and if you release it, the value that can be
modified with keys
+
and
-
is shown.
•when you reach the last function, press
F
to exit the program,
and the display resumes showing the gate status.
The following table shows the sequence of functions accessible in
ADVANCED PROGRAMMING:
INDICATOR-LIGHT:
If
is selected, the output functions as
a standard indicator-light (lighted at
opening and pause, flashing at closing,
and off when gate closed). Different figures
correspond to timed activation of the
output, which can be used (via a relay) to
power a courtesy lamp. Time can be
adjusted from
to
sec. in 1-second
steps, and from
to
min. in 10-
second steps.
= Standard indicator-light
from
to
= Timed output
GATE STATUS:
Exit from programming and return to gate
status viewing.
= Closed
= Now opening
= Stopped
= Open
= Pause
= "FAIL SAFE" tripped (chpt. 5.2)
= Now closing
= Now reversing