BLIZZARD 500-900 C
18
532103 - Rev.B
30
13 14
16
15
17
M
CO
M
OPEN CL
OSE
N LAMP
60W max
31
2.5
J6
OPEN A OPEN B FSW OP FSW CL ST
OP
EDGE
TX
-FSW
W
.L.
24 V
500 mA
max
1 2 3 4 5 6 7 8 9 10 11 12
{
2.5
29
J1
Tr
ansla
tion of the original instruc
tions
ENGLISH
Tr
ansla
tion of the original instruc
tions
ENGLISH
6.1 TERMINAL BOARDS AND CONNECTORS
Do not exceed the maximum load of the outputs.
J1
Terminal board for connecting the inputs and outputs (
29
).
10
J1 - Inputs and outputs
INPUTS
1
OPEN A
N.O. contact; if active, it commands the total opening of the gate.
If multiple contacts are used, they must be connected in parallel
(
30
).
2
OPEN B
N.O. contact; if active, it commands the partial opening of the gate.
If multiple contacts are used, they must be connected in parallel
(
30
).
3
FSW OP
N.C. contact for photocells during opening (§ 6.2).
4
FSW CL
N.C. contact for photocells during closing (§ 6.2).
5
STOP
N.C. stop contact (§ 6.2).
6
EDGE
N.C. contact for sensitive edges (§ 6.2).
OUTPUTS:
7-8
-
Negative for accessories.
9-10
+
Positive for accessories (24 V
"
/500 mA max).
11
TX-FSW
Fail-safe Test Output. Provides a negative pole for accessories supply
(100 mA max). It can be used to carry out a functional test of the
safety devices connected to the inputs FSW OP, FSW CL and EDGE. If
the test fails, the gear motor does control the movement.
Please refer to § 6.2 e § 7.4-
15
.
12
W.L.
Programmable output (100 mA max). When active, it provides a
negative for accessories. Default: indicator lamp (§ 7.4-
15
-
SP
).
J2
Rapid connector for inserting the GENIUS 5-pin radio receiver (option-
al accessory). Plug in the receiver only when the board is not powered.
J3
Rapid connector for inserting the encoder (optional accessory in
some models).
J4
Rapid connector for inserting the start-up capacitor. Alternatively, the
capacitor can be connected across terminals 14 and 15 of J6.
J5
Rapid connector for inserting the magnetic limit stop sensor.
J6
Terminal board for connecting the motor and flashing light (
31
).
The cable of the electric motor is connected during production.
11
J6 - Motor and Flashing Light
MOTOR OUTPUT:
13
COM
Common
Grey
14
OPEN
Opening
Black
15
CLOSE
Closing
Brown
FLASHING LIGHT OUTPUT:
16
N
Neutral
17
LAMP
Flashing lamp phase (230/115 V~): output active
during movement and during the pre-flashing set
in Programming (§ 7.4-
15
-
PF
).
Example of N.O. contacts connected in parallel
Example of N.C. contacts connected in series