LOGIC E: SEMI-AUTOMATIC
GATE STATUS
PULSES
SAFETY DEVICES
OPEN A
OPEN B
STOP
FSW OP
FSW CL
FSW CL/OP
EDGE
CLOSED
Opens
Opens partially
No effect (OPEN disa-
bled)
No effect (OPEN disa-
bled)
No effect
No effect (OPEN disa-
bled)
No effect (OPEN disa-
bled)
WHEN OPENING
Stops
Stops
Stops
§ 7.4-
15
-
oP
No effect
Stops. Opens when
disengaged
Reverses to closing
for 2 seconds
OPEN
Closes
Closes
Stops
No effect
No effect (OPEN disa-
bled)
No effect (OPEN disa-
bled)
No effect (OPEN disa-
bled)
WHEN CLOSING
Opens
Opens
Stops
No effect (memorizes
OPEN)
§ 7.4-
15
-
Ph
Stops. Opens when
disengaged
Reverses to opening
for 2 seconds*
STOPPED
Closes**
Closes**
No effect (OPEN disa-
bled)
No effect
No effect
No effect (OPEN disa-
bled)
No effect (OPEN disa-
bled)
LOGIC EP: SEMI-AUTOMATIC STEP-BY-STEP
GATE STATUS
PULSES
SAFETY DEVICES
OPEN A
OPEN B
STOP
FSW OP
FSW CL
FSW CL/OP
EDGE
CLOSED
Opens
Opens partially
No effect (OPEN disa-
bled)
No effect (OPEN disa-
bled)
No effect
No effect (OPEN disa-
bled)
No effect (OPEN disa-
bled)
WHEN OPENING
Stops
Stops
Stops
§ 7.4-
15
-
oP
No effect
Stops. Opens when
disengaged
Reverses to closing
for 2 seconds
OPEN
Closes
Closes
Stops
No effect
No effect (OPEN disa-
bled)
No effect (OPEN disa-
bled)
No effect (OPEN disa-
bled)
WHEN CLOSING
Stops
Stops
Stops
No effect (memorizes
OPEN)
§ 7.4-
15
-
Ph
Stops. Opens when
disengaged
Reverses to opening
for 2 seconds*
STOPPED
Restarts in the oppo-
site direction. Always
closes after STOP
Restarts in the oppo-
site direction. Always
closes after STOP
No effect (OPEN disa-
bled)
No effect (OPEN disa-
bled if it has to open)
No effect (OPEN disa-
bled if it has to close)
No effect (OPEN disa-
bled)
No effect (OPEN disa-
bled)
LOGIC C: DEAD-MAN
GATE STATUS
MAINTAINED COMMANDS
SAFETY DEVICES
OPEN A
OPEN B
STOP
FSW OP
FSW CL
FSW CL/OP
EDGE
CLOSED
Opens
No effect
No effect (OPEN A
disabled)
No effect (OPEN A
disabled)
No effect (OPEN B
disabled)
No effect (OPEN A
disabled)
No effect (OPEN disa-
bled)
WHEN OPENING
-
Stops
Stops
Stops (OPEN A disa-
bled)
No effect
Stops (OPEN disa-
bled)
Reverses to closing
for 2 seconds
OPEN
No effect
Closes
No effect (OPEN B
disabled)
No effect (OPEN A
disabled)
No effect (OPEN B
disabled)
No effect (OPEN B
disabled)
No effect (OPEN disa-
bled)
WHEN CLOSING
Stops
-
Stops
No effect
Stops (OPEN B disa-
bled)
Stops (OPEN disa-
bled)
Reverses to opening
for 2 seconds*
https://smartel.ua