Second Edition • Second Printing
Operator's Manual
Operating Instructions
Part No. 1278002GT
GS
™
-2669DC • GS
™
-3369DC • GS
™
-4069DC
39
Emergency Stop
Push in the red Emergency Stop button to the off
position at the ground controls or the platform
controls to stop all functions.
Repair any function that operates when either red
Emergency Stop button is pushed in.
Emergency Lowering
1
Turn the key switch to ground control.
2
Pull out both ground and platform red
Emergency Stop buttons to the on position.
3
Move and hold the emergency lowering
function enable toggle switch.
4
Move and hold the emergency lowering toggle
switch.
Operation from Ground
1
Be sure the battery pack is connected before
operating the machine.
2
Turn the key switch to ground control.
3
Pull out both ground and platform red
Emergency Stop buttons to the on position.
To Position Platform
1
At the control panel, press and hold the lift
function enable button.
2
Press the platform up or down button.
Drive and steer functions are not available from the
ground controls.
Operation from Platform
1
Be sure the battery pack is connected before
operating the machine.
2
Turn the key switch to platform control.
3
Pull out both ground and platform red
Emergency Stop buttons to the on position.
Controller Identification
These machines were produced with two different
styles of platform controls. Use the button pattern
on the platform controls to determine which
instructions apply to your machine.
Use these instructions if the
decal on your platform controls
has these buttons.
To Position Platform
1
Press and hold the high or
low speed lift enable button.
2
Press the platform up or
platform down button.
Summary of Contents for GS-2669DC