Section 4 • Repair Procedures
REV B
June 2007
Part No. 112657
GS-2668 RT • GS-3268 RT
4 - 39
13 Use the yellow platform down arrow to scroll to
generator option.
Result:
GENERATOR
AUTO
is showing in the
diagnostic display window. Press the lift
function enable button to activate or deactivate
the generator option.
Note: For this option to function correctly, the
machine must be equipped with the required
generator components and the software set to
GENERATOR
AUTO
or
GENERATOR
ON
.
14 Use the yellow platform down arrow to scroll to
outriggers option.
Result:
OUTRIGGERS
AUTO
is showing in the
diagnostic display window. Press the lift
function enable button to activate or deactivate
the outrigger option. Proceed to step 18.
Note: For this option to function correctly, the
machine must be equipped with the required
outrigger components and the software set to
OUTRIGGERS
AUTO
or
OUTRIGGERS
ON
.
15 Use the yellow platform down arrow to scroll to
beacons option.
Result:
BEACONS
OFF
is showing in the diagnostic
display window. Press the lift function enable
button to activate or deactivate the beacons
option.
Note: For this option to function, the machine must
be equipped with flashing beacons.
GROUND CONTROLS
16 Use the yellow platform down arrow to scroll to
generator option.
Result:
GENERATOR
OFF
is showing in the
diagnostic display window. Press the lift
function enable button to activate or deactivate
the generator option.
Note: For this option to function correctly, the
machine must be equipped with the required
generator components.
17 Use the yellow platform down arrow to scroll to
outriggers option.
Result:
OUTRIGGERS
OFF
is showing in the
diagnostic display window. Press the lift
function enable button to activate or deactivate
the outrigger option.
Note: For this option to function correctly, the
machine must be equipped with the required
outrigger components.
ANSI and CSA models with
all software revisions:
18 Use the yellow platform down arrow to scroll to
return to the main menu.
Result:
RETURN
TO
MAIN
MENU
is showing in the
diagnostic display window.
19 Press the lift function enable button.
Result:
SELECT
OPTIONS
is showing in the
diagnostic display window.
20 Push in the red Emergency Stop button to the
off position at the ground controls.